ZC-N2155 Công tắc hành trình Omron

643,000

Giao hàng COD toàn quốc

Out of stock

Mô Tả Sản Phẩm

ZC-N2155

Công tắc hành trình Omron

Small, High-precision Enclosed Switch

ActuatorModelApproved Standards
ULCSAEN
Plunger
zc []55 lineup1 1
ZC-D55
Panel mount plunger
zc []55 lineup1 2
ZC-Q55
Panel mount roller plunger
zc []55 lineup1 3
ZC-Q2255
Panel mount crossroller plunger
zc []55 lineup1 4
ZC-Q2155
Sealed roller plunger
zc []55 lineup1 5
ZC-N2255
Sealed crossroller plunger
zc []55 lineup1 6
ZC-N2155
Short hinge lever
zc []55 lineup1 7
ZC-W55
Hinge lever
zc []55 lineup1 8
ZC-W155
Short hinge roller lever
zc []55 lineup1 9
ZC-W255
Hinge roller lever
zc []55 lineup1 10
ZC-W2155
One-way action short hinge roller lever
zc []55 lineup1 11
ZC-W355
One-way action hinge roller lever
zc []55 lineup1 12
ZC-W3155
Note: 1. Use molded terminal models when using the Switch under one of the following conditions: a) dusty, b) high
amount of dripping oil, or c) high humidity.
2. Models are available with lead outlets in three positions: right-hand, left-hand, and underside.

Ratings

Rated voltageNon-inductive load (A)Inductive load (A)
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125 VAC
250 VAC
10
10
3
2.5
1.5
1.25
10
10
5
3
2.5
1.5
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
10
10
6
0.5
0.25
3
3
3
0.4
0.2
1.5
1.5
1.5
0.4
0.2
6
6
5
0.05
0.03
5
5
5
0.05
0.03
2.5
2.5
2.5
0.05
0.03
Inrush currentNC30 A max.
NO15 A max.
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
5. The above ratings were tested under the following conditions according.
(1) Ambient temperature:+20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency:20 operations/min.

Characteristics

Degree of protectionsIP67
DurabilityMechanical10,000,000 operations min.
Electrical500,000 operations min.
Operating speed0.05 mm/s to 0.5 m/s *1
Operating
frequency
Mechanical120 operations/min
Electrical20 operations/min
Insulation resistance100 MΩ min. (at 500 VDC)
Contact resistance15 mΩ max. (initial value for the builtin switch when tested alone)
Dielectric
strength
Between non-continuous terminals1,000 VAC, 50/60 Hz for 1 min
Between each terminal and non-
current-carrying metal parts
2,000 VAC, 50/60 Hz for 1 min
Rated insulation voltage (Ui)1,000 VAC
Pollution degree (operating environment)3 (IEC947-5-1)
Short-circuit protective device10 A-fuse type gG (IEC 60269)
Protection against electric shockClass II
Proof tracking index (PTI)175
Switch categoryD (IEC335)
Rated operating current (Ie)10 A
Rated operating voltage (Ue)250 VAC
Vibration
resistance
Malfunction10 to 55 Hz, 1.5-mm double amplitude *2
Shock
resistance
Destruction1,000 m/s2 max.
Malfunction300 m/s2 max. (in case of plunger model) *1 *2
Ambient operating temperature-10°C to +80°C (with no icing)
Ambient operating humidity35% to 95%RH
WeightApprox. 92 g (in case of ZC-Q22(21)55)

*1. Only for models with plungers. (Contact your OMRON representative for information on other models.)
*2. Less than 1 ms under a free state at the operating limits.