| Product characteristics |
|---|
| Electrical design | PNP/NPN |
| Output function | normally closed |
| Sensing range [mm] | 12 |
| Housing | threaded type |
| Dimensions [mm] | M18 x 1 / L = 70 |
| Application |
|---|
| Special feature | Gold-plated contacts; Increased sensing range |
| Application | Use in mobile and harsh applications |
| Electrical data |
|---|
| Operating voltage [V] | 10…36 DC |
| Current consumption [mA] | < 10; (only in 3-wire operation) |
| Protection class | II |
| Reverse polarity protection | yes |
| Outputs |
|---|
| Electrical design | PNP/NPN |
| Output function | normally closed |
| Max. voltage drop switching output DC [V] | 2.5 |
| Minimum load current [mA] | 2; (only in 2-wire operation) |
| Max. leakage current [mA] | 0.5; (only in 2-wire operation) |
| Permanent current rating of switching output DC [mA] | 100 |
| Switching frequency DC [Hz] | 200 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Detection zone |
|---|
| Sensing range [mm] | 12 |
| Real sensing range Sr [mm] | 12 ± 10 % |
| Operating distance [mm] | 0…9.72 |
| Increased sensing range | yes |
| Accuracy / deviations |
|---|
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.45 / copper: 0.35 |
| Hysteresis [% of Sr] | 1…20 |
| Switch point drift [% of Sr] | -10…10 |
| Operating conditions |
|---|
| Ambient temperature [°C] | -40…85 |
| Protection | IP 67; IP 69K |
| Tests / approvals |
|---|
| EMC | | automotive area | | | noise emission and noise interference according to the automotive directive 95/54/EC | E1 type approval | | noise immunity according to DIN ISO 11452-2 | 100 V/m | | conducted interference acc. to ISO 7637-2 | | | pulse | 1 2 3a 3b 4 5 | | severity level | IV IV IV IV IV IV | | failure criterion | C C A A A C | | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | | EN 61000-4-3 HF radiated | 10 V/m | | EN 61000-4-4 Burst | 2 kV | | EN 61000-4-5 Surge | 0,5 kV mains line to line | | EN 61000-4-6 HF conducted | 10 V | | EN 55011 | class B |
|
| Vibration resistance | | EN 60068-2-6 Fc | 20 g (10…3000 Hz) / -20…50 °C | | 50 sweep cycles per frequency; 1 octave per minute in 3 axes |
|
| Shock resistance | | EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40…85 °C |
|
| Continuous shock resistance | | EN 60068-2-27 | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20…50 °C |
|
| Fast temperature change | | EN 60068-2-14 Na | TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
|
| Salt spray test | | EN 60068-2-52 Kb | severity level 5 (4 test cycles) |
|
| MTTF [years] | 1195 |
| UL approval | | Ta | -40…85 °C | | Enclosure type | Type 1 | | voltage supply | Limited Voltage/Current | | File number UL | E174191 |
|
| Mechanical data |
|---|
| Weight [g] | 55.6 |
| Housing | threaded type |
| Mounting | non-flush mountable |
| Dimensions [mm] | M18 x 1 / L = 70 |
| Thread designation | M18 x 1 |
| Materials | housing: stainless steel; sensing face: LCP natural; connector housing: PEI; lock nuts: brass |
| Displays / operating elements |
|---|
| Display | | switching status | 4 x 90° LED, yellow |
|
| Accessories |
|---|
| Accessories (supplied) | |
| Remarks |
|---|
| Pack quantity | 1 pcs. |
| Electrical connection – plug |
|---|
| Connector: 1 x M12; Contacts: gold-plated |