HL-5100
Công tắc hành trình Omron
Economical, Miniature Limit Switch Boasting Rigid Construction
last update: September 24, 2012
Actuator | Model | |
---|---|---|
Roller lever | HL-5000 * | |
Adjustable roller lever | HL-5030 * | |
Adjustable rod lever | HL-5050 * | |
Sealed plunger | HL-5100 * | |
Sealed roller plunger | HL-5200 | |
Coil spring | HL-5300 |
standards. When placing an order, add the code to the model number to indicate if ground terminal/M5 tapping on the
rear side is required.
-G: with ground terminal/M5 tapping on the rear side.
Ratings
Rated voltage | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125 VAC 250 VAC |
5 5 |
1.5 1 |
0.7 0.5 |
3 3 |
2 1.5 |
1 0.8 |
||
12 VDC 24 VDC 125 VDC 250 VDC |
5 5 |
3 3 |
4 4 |
3 3 |
||||
0.4 0.4 |
0.2 0.2 |
– | – | – |
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Inrush current | NC | 24 A max. |
---|---|---|
NO | 12 A max. |
Characteristics
Degree of protection | IP65 | |
---|---|---|
Durability * | Mechanical | 10,000,000 operations min. (under rated conditions) |
Electrical | See the following Electrical Durability. | |
Operating speed | 5 mm/s to 0.5 m/s | |
Operating frequency | Mechanical | 120 operations/min |
Electrical | 30 operations/min | |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |
Contact resistance | 25 mΩ max. (initial value) | |
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity | |
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground | ||
1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal part | ||
Rated frequency | 50/60 Hz | |
Vibration resistance | Malfunction | 10 to 55 Hz, 1.5-mm double amplitude |
Shock resistance | Destruction | 1,000 m/s2 max. |
Malfunction | 300 m/s2 max. | |
Ambient operating temperature | -5°C to +65°C (with no icing) | |
Ambient operating humidity | 35% to 95%RH | |
Weight | Approx. 130 to 190 g |
2. The above characteristics may vary depending on the model. For further details, contact your OMRON sales
representative.
* The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH.
Contact your OMRON sales representative for more detailed information on other operating environments.