HL-5100 Công tắc hành trình Omron

792,000

Giao hàng COD toàn quốc

Mô Tả Sản Phẩm

HL-5100

Công tắc hành trình Omron

Economical, Miniature Limit Switch Boasting Rigid Construction

Actuator Model
Roller lever
hl 5000 lineup1 1
HL-5000 *
Adjustable roller lever
hl 5000 lineup1 2
HL-5030 *
Adjustable rod lever
hl 5000 lineup1 3
HL-5050 *
Sealed plunger
hl 5000 lineup1 4
HL-5100 *
Sealed roller plunger
hl 5000 lineup1 5
HL-5200
Coil spring
hl 5000 lineup1 6
HL-5300
* HL-5000 Limit Switches are offered with a choice of ground terminal/M5 tapping on the rear side conforming to various
standards. When placing an order, add the code to the model number to indicate if ground terminal/M5 tapping on the
rear side is required.
-G: with ground terminal/M5 tapping on the rear side.

Ratings

Rated voltage Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC
250 VAC
5
5
1.5
1
0.7
0.5
3
3
2
1.5
1
0.8
12 VDC
24 VDC
125 VDC
250 VDC
5
5
3
3
4
4
3
3
0.4
0.4
0.2
0.2
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Inrush current NC 24 A max.
NO 12 A max.

Characteristics

Degree of protection IP65
Durability * Mechanical 10,000,000 operations min. (under rated conditions)
Electrical See the following Electrical Durability.
Operating speed 5 mm/s to 0.5 m/s
Operating frequency Mechanical 120 operations/min
Electrical 30 operations/min
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 25 mΩ max. (initial value)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground
1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal part
Rated frequency 50/60 Hz
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max.
Ambient operating temperature -5°C to +65°C (with no icing)
Ambient operating humidity 35% to 95%RH
Weight Approx. 130 to 190 g
Note: 1. The above figures are initial values.
2. The above characteristics may vary depending on the model. For further details, contact your OMRON sales
representative.
* The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH.
Contact your OMRON sales representative for more detailed information on other operating environments.