H7CX-A-N Omron bộ đếm cỡ 48x48mm

3,984,000

Giao hàng COD toàn quốc

Mô Tả Sản Phẩm

H7CX-A-N

Omron Bộ đếm đa năng một trạng thái  hiển thị số, kích thước 48x48mm Nguồn cấp: 100-240VAC

  • Hiển thị negative trasmissive LCD, 6 số
  • Chức năng đếm: 1-stage counter / 1-stage counter with total counter
  • Tốc độ: 30Hz / 5kHz
  • Ngõ vào: NPN/PNP
  • Ngõ ra: SPDT-3A 250VAC/30VDC; NPN 100mA, 30VDC
  • Các chế độ ngõ ra: N, F, C, R, K-1, P, Q, A, K-2, D, L
  • Tiêu chuẩn: UL, CSA, EN, CE

Thông số kĩ thuật

ModelsH7CX-A114[]-NH7CX-A11[]-NH7CX-A4[]-N
ClassificationPreset counter
Configuration1-stage preset counter, 1-stage preset counter with total counter (selectable) *1
RatingsPower supply
voltage*2
100 to 240 VAC, 50/60 Hz
24 VAC, 50/60 Hz or 12 to 24 VDC
100 to 240 VAC, 50/60 Hz
12 to 24 VDC
Operating voltage
fluctuation range
85% to 110% of rated supply voltage (12 to 24 VDC: 90% to 110%)
Power
consumption
Approx. 9.4 VA at 100 to 240 VAC, Approx. 7.2 VA/4.7 W at 24 VAC/12 to 24 VDC, Approx.
3.7 W at 12 to 24 VDC
Mounting methodFlush mounting or surface mountingFlush mounting
External connections11-pin socketScrew terminals
Degree of protectionIEC IP66, UL508 Type 4X (indoors) for panel surface only and only when Y92S-29
Waterproof Packing is used.
Input signalsCP1, CP2, reset, and total reset
CounterMaximum
counting speed
30 Hz (minimum pulse width: 16.7 ms) or 10 kHz (minimum pulse width: 0.05 ms)
(selectable) (ON/OFF ratio 1:1) *Common setting for CP1 and CP2
Input modeIncrement, decrement, increment/decrement (UP/DOWN A (command input), UP/DOWN
B (individual inputs), or UP/DOWN C (quadrature inputs))
Output modeN, F, C, R, K-1, P, Q, A, K-2, D, and L.
One-shot output
time
0.01 to 99.99 s
Reset systemExternal (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and
automatic reset (internal according to C, R, P, and Q mode operation)
TachometerRefer to the separate table for tachometer function ratings.
Prescaling functionYes (0.001 to 9.999)Yes (0.001 to 99.999)Yes (0.001 to 9.999)
Decimal point adjustmentYes (rightmost 3 digits)
Sensor waiting time290 ms max. (Control output is turned OFF and no input is accepted during sensor
waiting time.)
Input methodNo-voltage inputs:
ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω)
ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Voltage input:
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
No-voltage input/voltage input (selectable)
External power supply12 VDC (±10%), 100 mA (except for H7CX-A[]D models) Refer to on page for details.
Control outputContact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1), Minimum applied load:
10 mA at 5 VDC (failure level: P, reference value)
Transistor output: NPN open collector, 100 mA at 30 VDC, Residual voltage: 1.5 VDC
max. (approx. 1 V), Leakage current: 0.1 mA max.
Display*37-segment, negative
transmissive LCD
Character height
Count value: 12 mm (red)
Set value: 6 mm (green)
7-segment, negative
transmissive LCD
Character height
Count value: 10 mm (red)
Set value: 6 mm (green)
7-segment, negative
transmissive LCD
Character height
Count value: 12 mm (red,
green, or orange selectable)
Set value: 6 mm (green)
Digits4 digits
-999 to 9999
(-3 digits to +4 digits)
6 digits
-99999 to 999999
(-5 digits to +6 digits)
4 digits
-999 to 9999
(-3 digits to +4 digits)
Memory backupEEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating temperature
range
-10 to 55°C (-10 to 50°C if Counter/Tachometers are mounted side by side) (with no
icing or condensation)
Storage temperature range-25 to 70°C (with no icing or condensation)
Operating humidity range25% to 85%
Case colorBlack (N1.5) (Optional Front Panels are available to change the Front Panel color to light
gray or white.)
AttachmentsFlush mounting adapter,
waterproof packing,
terminal cover
ModelsH7CX-A[]-NH7CX-A4W[]-NH7CX-AW[]-N/-AU[]-N
ClassificationPreset counterPreset counter/tachometer
Configuration1-stage preset counter,
1-stage preset counter with
total counter (selectable) *1
1-stage/2-stage preset
counter, total and preset
counter *1, batch counter,
dual counter, and twin
counter (selectable)
1-stage/2-stage preset
counter, total and preset
counter *1, batch counter,
dual counter, twin counter,
and tachometer (selectable)
RatingsPower supply
voltage*2
100 to 240 VAC, 50/60 Hz
12 to 24 VDC
100 to 240 VAC at 50/60 Hz
24 VAC at 50/60 Hz or 12 to
24 VDC
12 to 24 VDC
Operating voltage
fluctuation range
85% to 110% of rated supply voltage (12 to 24 VDC: 90% to 110%)
Power
consumption
Approx. 9.4 VA at 100 to 240 VAC, Approx. 7.2 VA/4.7 W at 24 VAC/12 to 24 VDC, Approx.
3.7 W at 12 to 24 VDC
Mounting methodFlush mounting
External connectionsScrew terminals
Degree of protectionIEC IP66, UL508 Type 4X (indoors) for panel surface only and only when Y92S-29
Waterproof Packing is used.
Input signalsCP1, CP2, reset, and total
reset
CP1, CP2, reset 1, and reset 2
CounterMaximum
counting speed
30 Hz (minimum pulse width: 16.7 ms) or 10 kHz (minimum pulse width: 0.05 ms)
(selectable) (ON/OFF ratio 1:1) *Common setting for CP1 and CP2
Input modeIncrement, decrement, increment/decrement (UP/DOWN A (command input), UP/DOWN
B (individual inputs), or UP/DOWN C (quadrature inputs))
Output modeN, F, C, R, K-1, P, Q, A, K-2,
D, and L.
N, F, C, R, K-1, P, Q, A, K-2, D, L, and H.
One-shot output
time
0.01 to 99.99 s
Reset systemExternal (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and
automatic reset (internal according to C, R, P, and Q mode operation)
TachometerRefer to the separate table for tachometer function ratings.
Prescaling functionYes (0.001 to 99.999)Yes (0.001 to 9.999)Yes (0.001 to 99.999)
Decimal point adjustmentYes (rightmost 3 digits)
Sensor waiting time290 ms max. (Control output is turned OFF and no input is accepted during sensor
waiting time.)
Input methodNo-voltage inputs:
ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω)
ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Voltage input:
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
No-voltage input/voltage input (selectable)
External power supply12 VDC (±10%), 100 mA (except for H7CX-A[]D models) Refer to on page for details.
Control outputContact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1), Minimum applied load:
10 mA at 5 VDC (failure level: P, reference value)
Transistor output: NPN open collector, 100 mA at 30 VDC, Residual voltage: 1.5 VDC
max. (approx. 1 V), Leakage current: 0.1 mA max.
Display*37-segment, negative
transmissive LCD
Character height
Count value: 10 mm (red,
green, or orange selectable)
Set value: 6 mm (green)
7-segment, negative
transmissive LCD
Character height
Count value: 12 mm (red,
green, or orange selectable)
Set value: 6 mm (green)
7-segment, negative
transmissive LCD
Character height
Count value: 10 mm (red,
green, or orange selectable)
Set value: 6 mm (green)
Digits6 digits
-99999 to 999999
(-5 digits to +6 digits)
4 digits
-999 to 9999
(-3 digits to +4 digits)
6 digits
-99999 to 999999
(-5 digits to +6 digits),
tachometer: 0 to 999999
Memory backupEEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating temperature
range
-10 to 55°C (-10 to 50°C if Counter/Tachometers are mounted side by side) (with no
icing or condensation)
Storage temperature range-25 to 70°C (with no icing or condensation)
Operating humidity range25% to 85%
Case colorBlack (N1.5) (Optional Front Panels are available to change the Front Panel color to light
gray or white.)
AttachmentsFlush mounting adapter, waterproof packing, terminal
cover
Flush mounting adapter,
waterproof packing,
terminal cover, label for
DIP switch settings

Để xem các loại bộ đếm Omron khác tại đây

Để tải tài liệu Omron chính hãng tại đây

Reviews

There are no reviews yet.

Be the first to review “H7CX-A-N Omron bộ đếm cỡ 48x48mm”

Your email address will not be published. Required fields are marked *