G9SA-321-T30
Rơ le an toàn
The G9SA Series Offers a Complete Line-up of Compact Units
• Four kinds of 45-mm wide Units are available:
AC/DC24
A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a Two-hand Controller.
Also available are 17.5-mm wide Expansion Units with 3 poles and 3 OFF-delay poles.
• Simple expansion connection.
• OFF-delay models have 15-step OFF-delay settings.
• Conforms to EN ISO13849-1 (PLe/Safety Category 4).
• Both DIN track mounting and screw mounting are possible.
G9SA Master Units
Emergency-stop Units
Main contacts | Auxiliary contact | Number of input channels | Rated voltage | Model |
---|---|---|---|---|
3PST-NO | SPST-NC | 1 channel or 2 channels possible | 24 VAC/VDC | G9SA-301 |
100 to 240 VAC | ||||
5PST-NO | 24 VAC/VDC | G9SA-501 | ||
100 to 240 VAC |
Emergency-stop OFF-delay Units
Main contacts |
OFF-delay contacts |
Auxiliary contact |
Number of input channels |
OFF-delay time |
Rated voltage | Model |
---|---|---|---|---|---|---|
3PST-NO | DPST-NO | SPST-NC | 1 channel or 2 channels possible |
7.5 s | 24 VAC/VDC | G9SA-321-T075 |
100 to 240 VAC | ||||||
15 s | 24 VAC/VDC | G9SA-321-T15 | ||||
100 to 240 VAC | ||||||
30 s | 24 VAC/VDC | G9SA-321-T30 | ||||
100 to 240 VAC |
* The following 15-step OFF-delay time settings are available:
T075: 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6, 6.5, 7, and 7.5 s
T15: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, and 15 s
T30: 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, and 30 s
Two-hand Controller
Main contacts | Auxiliary contact | Number of input channels | Rated voltage | Model |
---|---|---|---|---|
3PST-NO | SPST-NC | 2 channels | 24 VAC/VDC | G9SA-TH301 |
100 to 240 VAC |
Expansion Unit
Expansion Unit
The Expansion Unit connects to a G9SA-301, G9SA-501, G9SA-321, or G9SA-TH301.
Main contacts | Auxiliary contact | Model |
---|---|---|
3PST-NO | SPST-NC | G9SA-EX301 |
Expansion Units with OFF-delay Outputs
The Expansion Unit connects to a G9SA-301, G9SA-501 or G9SA-321.
Main contact form | Auxiliary contact | OFF-delay time | Model |
---|---|---|---|
3PST-NO | SPST-NC | 7.5 s | G9SA-EX031-T075 |
15 s | G9SA-EX031-T15 | ||
30 s | G9SA-EX031-T30 |
* The following 15-step OFF-delay time settings are available:
T075: 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6, 6.5, 7, and 7.5 s
T15: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, and 15 s
T30: 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, and 30 s