E5EC-QX2ASM-800
Điều khiển nhiệt độ Omron
48 × 96 mm. Large White PV Display That’s Easier to Read. Easy to Use, from Model Selection to Setup and Operation. A Complete Range of I/O Capacities, Functions, and Performance. Handles More Applications.
Model Number Legend
Models with Screw Terminals
E5EC-800 48 × 96 mm
Control output 1 | Control output 2 |
Auxiliary output |
Commu- nications |
Heater burnout |
Event inputs |
Power supply voltage |
Model |
---|---|---|---|---|---|---|---|
Relay output | – | Two | – | – | – | 100 to 240 VAC |
E5EC-RX2ASM-800 |
Voltage output | – | E5EC-QX2ASM-800 | |||||
Linear current output | – | E5EC-CX2ASM-800 | |||||
Relay output | Relay output | E5EC-RR2ASM-800 | |||||
Voltage output | Relay output | E5EC-QR2ASM-800 | |||||
Linear current output | Relay output | E5EC-CR2ASM-800 | |||||
Relay output | – | 24 VAC/ VDC |
E5EC-RX2DSM-800 | ||||
Voltage output | – | E5EC-QX2DSM-800 | |||||
Linear current output | – | E5EC-CX2DSM-800 | |||||
Relay output | Relay output | E5EC-RR2DSM-800 | |||||
Voltage output | Relay output | E5EC-QR2DSM-800 | |||||
Linear current output | Relay output | E5EC-CR2DSM-800 | |||||
Relay output | Relay output | RS-485 | One | Two | 100 to 240 VAC |
E5EC-RR2ASM-808 | |
Voltage output | Relay output | E5EC-QR2ASM-808 | |||||
Relay output | Relay output | 24 VAC/ VDC |
E5EC-RR2DSM-808 | ||||
Voltage output | Relay output | E5EC-QR2DSM-808 | |||||
Relay output | Relay output | – | Four | 100 to 240 VAC |
E5EC-RR2ASM-810 | ||
Voltage output | Relay output | E5EC-QR2ASM-810 | |||||
Relay output | Relay output | 24 VAC/ VDC |
E5EC-RR2DSM-810 | ||||
Voltage output | Relay output | E5EC-QR2DSM-810 | |||||
Linear current output | Relay output | RS-485 | – | Two | 100 to 240 VAC |
E5EC-CR2ASM-804 | |
Linear current output | Relay output | 24 VAC/ VDC |
E5EC-CR2DSM-804 | ||||
Relay output (Open) * | Relay output (Close) * |
– | – | – | – | 100 to 240 VAC |
E5EC-PR0ASM-800 |
Relay output (Open) * | Relay output (Close) * |
Two | E5EC-PR2ASM-800 | ||||
Relay output (Open) * | Relay output (Close) * |
RS-485 | Two | E5EC-PR2ASM-804 |
* Position proportional control model.
Note: Draw-out-type models of the E5EC-800 are available. Ask your OMRON representative for details.
Heating and Cooling Control
Using Heating and Cooling Control
(1) Control Output Assignment
If there is no control output 2, an auxiliary output is used as the cooling control output.
If there is a control output 2, the two control outputs are used for heating and cooling.
(It does not matter which output is used for heating and which output is used for cooling.)
(2) Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.
Optional Products (Order Separately)
Terminal Covers
Model |
---|
E53-COV24 |
Waterproof Packing
Model |
---|
Y92S-P9 |
Note: This Waterproof Packing is provided with the Digital Temperature Controller.
Waterproof Cover
Model |
---|
Y92A-49N |
Front Port Cover
Model |
---|
Y92S-P7 |
Note: This Front Port Cover is provided with the Digital Temperature Controller.
Mounting Adapter
Model |
---|
Y92F-51 (Two Adapters are included.) |
Note: This Mounting Adapter is provided with the Digital Temperature Controller.
Current Transformers (CTs)
Hole diameter | Model |
---|---|
5.8 mm | E54-CT1 |
5.8 mm | E54-CT1L * |
12.0 mm | E54-CT3 |
12.0 mm | E54-CT3L * |
* Lead wires are included with these CTs. If UL certification is required, use these CTs.
Reviews