E3X-HD10
Cảm biến sợi quang Omron
Surprisingly Stable Detection with Your Finger tip. Exceptionally easy operation and stabilizing technology reduce maintenance cost
Fiber Amplifier Units
Standard models
| Appearance | Connecting method | Model | |
|---|---|---|---|
| NPN output | PNP output | ||
![]() | Pre-wired (2 m) | E3X-HD11 2M | E3X-HD41 2M |
![]() | Wire-saving Connector | E3X-HD6 | E3X-HD8 |
![]() | M8 Connector | E3X-HD14 | E3X-HD44 |
Model for Sensor Communications Unit
| Appearance | Model | Applicable Sensor Communications Unit |
|---|---|---|
![]() | E3X-HD0 | E3X-ECT |
| E3X-CRT |
Accessories (sold separately)
Wire-saving connectors (Required for models for Wire-saving Connectors.)
Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately. * Protective stickers: provided.
| Type | Appearance | Cable length | Number of conductors | Model |
|---|---|---|---|---|
| Master connector | ![]() | 2 m | 3 | E3X-CN11 |
| Slave connector | ![]() | 1 | E3X-CN12 |
Sensor I/O Connectors (Required for models with M8 Connectors.)
Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately.
| Size | Cable | Appearance | Cable type | Models | ||
|---|---|---|---|---|---|---|
| M8 | Standard cable | Straight | ![]() | 2m | 4-wire | XS3F-M421-402-A |
| 5m | XS3F-M421-405-A | |||||
| L-shaped | ![]() | 2m | XS3F-M422-402-A | |||
| 5m | XS3F-M422-405-A | |||||
Mounting Bracket
A Mounting Bracket is not provided with the Fiber Amplifier Unit and must be ordered separately as required.
| Appearance | Model | Quantity |
|---|---|---|
![]() | E39-L143 | 1 |
DIN Track
A Din Track is not provided with the Fiber Amplifier Unit and must be ordered separately as required.
| Appearance | Type | Model | Quantity |
|---|---|---|---|
![]() | Shallow type, total length: 1 m | PFP-100N | 1 |
| Shallow type, total length: 0.5 m | PFP-50N | ||
| Deep type, total length: 1 m | PFP-100N2 |
End Plate
Two End Plates are provided with the Sensor Communications Unit.
End Plates are not provided with the Fiber Amplifier Unit and must be ordered separately as required.
| Appearance | Model | Quantity |
|---|---|---|
![]() | PFP-M | 1 |
Ratings and Specifications
| Type | Standard | Model for Sensor Communications Unit *1 | |||
|---|---|---|---|---|---|
| NPN output | E3X-HD11 | E3X-HD6 | E3X-HD14 | E3X-HD0 | |
| PNP output | E3X-HD41 | E3X-HD8 | E3X-HD44 | ||
| Connecting method | Pre-wired | Wire-saving Connector *2 | M8 connector | Communications Unit connector | |
| Light source (wavelength) | Red, 4-element LED (625 nm) | ||||
| Power supply voltage | 12 to 24 VDC ±10%, ripple (P-P) 10% max. | Supplied from the connector through the Sensor Communications Unit | |||
| Power consump tion | Normal mode | 720 mW max. (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC) | |||
| Eco ON | 530 mW max. (Current consumption: 22 mA max. at 24 VDC, 44 mA max. at 12 VDC) | ||||
| Eco LO | 640 mW max. (Current consumption: 26 mA max. at 24 VDC, 53 mA max.at 12 VDC) | – | |||
| Control output | Load power supply voltage: 26.4 VDC max., open- collector output Load current: Groups of 1 to 3 Amplifier Units: 100mA max., Groups of 4 to 16 Amplifier Units: 20mA max. Residual voltage: At load current of less than 10 mA: 1 V max., At load current of 10 to 100 mA: 2 V max. OFF current: 0.1 mA max. | – | |||
| Protection circuits | Power supply reverse polarity protection, output short-circuit protection and output reverse polarity protection | Power supply reverse polarity protection and output short- circuit protection | |||
| Response time | Super-high-speed mode (SHS) *3 | NPN outputs: Operate or reset: 50 μs PNP outputs: Operate or reset: 55 μs | – | ||
| High-speed Mode (HS) | Operate or reset: 250 μs (default setting) | ||||
| Standard Mode (STND) | Operate or reset: 1 ms | ||||
| Giga-power Mode (GIGA) | Operate or reset: 16 ms | ||||
| Maximum connectable Units | 16 units | with E3X-CRT: 16 units with E3X-ECT: 30 units | |||
| Mutual interference prevention | Possible for up to 10 units (optical communications sync) *3 | ||||
| Auto power control (APC) | Always ON | ||||
| Other functions | Power tuning, differential detection, DPC, timer (OFF-delay, ON-delay, or one-shot), zero reset, resetting settings, and Eco mode | ||||
| Ambient illumination (Receiver side) | Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. | ||||
| Ambient temperature range | OOperating: Groups of 1 to 2 Amplifiers: -25 to 55°C, Groups of 3 to 10 Amplifiers: -25 to 50°C, Groups of 11 to 16 Amplifiers: -25 to 45°C Storage: -30 to 70°C (with no icing or condensation) | Operating: Groups of 1 to 2 Amplifiers: 0 to 55°C, Groups of 3 to 10 Amplifiers: 0 to 50°C, Groups of 11 to 16 Amplifiers: 0 to 45°C, Groups of 17 to 30 Amplifiers: 0 to 40°C Storage: -30 to 70°C (with no icing or condensation) | |||
| Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | ||||
| Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
| Dielectric strength | 1,000 VAC at 50/60 Hz for 1 minute | ||||
| Vibration resistance (destruction) | 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | 10 to 150 Hz with a 0.7-mm double amplitude for 80 minutes each in X, Y, and Z directions | |||
| Shock resistance (destruction) | 500 m/s2 for 3 times each in X, Y, and Z directions | 150 m/s2 for 3 times each in X, Y, and Z directions | |||
| Degree of protection | IEC 60529 IP50 (with Protective Cover attached) | – | |||
| Weight (packed state/unit only) | Approx. 105 g/ Approx. 65 g | Approx. 60 g/ Approx. 20 g | Approx. 70 g/ Approx. 25 g | Approx. 65 g/Approx. 25 g | |
| Materials | Case | Polycarbonate (PC) | Heat-resistant ABS (connector: PBT) | ||
| Cover | Polycarbonate (PC) | ||||
| Cable | PVC | – | |||
| Accessories | Instruction Manual | ||||
*1. The E3X-ECT EtherCAT Sensor Communications Unit and the E3X-CRT CompoNet Sensor Communications Unit can be used.
*2. Use either the E3X-CN11 (master connector, 3 conductors) or the E3X-CN12 (slave connector, 1 conductor).
*3. The communications function and mutual interference prevention function are disabled when the detection mode is set to Super-high-speed mode (SHS).
When including E3X-DA-S with activated power tuning, mutual interference prevention is possible for up to 6 units.
When including E3X-MDA with activated power tuning, mutual interference prevention is possible for up to 5 units.


























Reviews