EE-SPX613 1M
Liquid Level Photomicrosensor with operation mode and sensitivity selectors for easy application
Thông số kĩ thuật
| ensing method | Through-beam type |
|---|---|
| Operation mode | Dark-ON/Light-ON (selectable) |
| Applicable pipe | Any 6 to 13 mm diameter pipe with a wall thickness of 1 mm that is made of FEP or any other material as transparent as FEP. |
| Standard sensing object | Liquids in pipes (High-viscosity liquids or liquids with floating materials may not be detected) |
| Light source (Peak wavelength) | GaAs infrared LED (940 nm) |
| Indicator | Light indicator GaP (Red LED: Peak wavelength of 700 nm) |
| Power supply voltage | 12 to 24 VDC ±10% (ripple (p-p)5% max.) |
| Current consumption | Average: 30 mA max./Peak: 80 mA max. |
| Control output (Output type) | NPN Open collector output |
| Control output (Load power supply voltage) | 5 to 24 VDC |
| Control output (Load current) | 100 mA max. |
| Control output (Residual voltage) | 0.8 V max. (at 100 mA load current) 0.4 V max. (at 40 mA load current) |
| Illumination on the surface receiver | Incandescent light, sunlight: 3000 lx max. |
| Ambient temperature | Operating: -10 to 55 ℃ Storage: -25 to 65 ℃ (with no icing or condensation) |
| Ambient humidity | Operating: 5 to 85% RH Storage: 5 to 95% RH (with no icing or condensation) |
| Vibration resistance | 10 to 500 Hz, 1.0-mm single amplitude or acceleration 150 m/s**2, 3 times each in X, Y, and Z directions (11 min/sweeps) |
| Shock resistance | 500 m/s**2, 3 times each in X, Y, and Z directions |
| Degree of protection (IEC60529) | IP50 |
| Connection method | Pre-wired models |
| Cable length | 1 m |
| Material | Case: Polycarbonate(PC) Cover: Polycarbonate(PC) |
| Accessories | Support belt slip protection tube Instruction manual |