K8DS-PZ1 Rơ le bảo vệ pha Omron
Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment. 17.5 mm (W). One SPDT output relays
• Greater resistance to inverter noise.
• Monitor undervoltages, phase sequence, and phase loss in threephase three-wire circuits with one unit.
• One SPDT output relay, 5 A at 250 VAC (resistive load).
• World-wide power specifications supported by one unit. (Set with a rotary switch.)
• Relay status can be monitored using LED indicator.
ast update: April 01, 2014
Rated input voltage* | Model | |
---|---|---|
3-phase 3-wire mode | 200, 220, 230, or 240 VAC | K8DS-PZ1 |
380, 400, 415, or 480 VAC | K8DS-PZ2 |
Note: The input range is set with a rotary switch.
* The power supply voltage is the same as the rated input voltage.
last update: March 1, 2019
Ratings
Rated input voltage | K8DS-PZ1 | Three-phase, three-wire Mode: 200, 220, 230, or 240 VAC |
---|---|---|
K8DS-PZ2 | Three-phase, three-wire Mode: 380, 400, 415, or 480 VAC | |
Input load | K8DS-PZ1: Approx. 1.7 VA K8DS-PZ2: Approx. 2.8 VA |
|
Operating value setting range (OVER/UNDER) (ASY) |
Overvoltage/Undervoltage 2% to 30% of rated input voltage Asymmetry 5% to 22% of rated input voltage |
|
Operating value (OVER/UNDER) | Operates at 100% of set value. | |
Operating value (ASY.) | Asymmetry operating value = Rated input voltage × Asymmetry set value (%) The asymmetry operation will function when the potential difference between the highest and lowest voltage phases equals or exceeds the asymmetry operating value. |
|
Reset value | 5% of operating value (fixed) | |
Reset method | Automatic reset | |
Operating time setting range (T) |
Overvoltage/ Undervoltage |
0.1 to 30 s |
Asymmetry | 0.1 to 30 s | |
Phase sequence | 0.1 s±0.05 s | |
Phase loss | 0.1 s max. | |
Power ON lock time (LOCK) | 1 s±0.5 s | |
Indicators | Power (PWR): Green, Relay output (RY): Yellow, Alarm outputs (ALM): Red | |
Output relays | One SPDT relay output | |
Output relay ratings | Rated load Resistive load 5 A at 250 VAC 5 A at 30 VDC Maximum switching capacity: 1,250 VA, 150 W Minimum load: 5 VDC, 10 mA (reference values) Mechanical life: 10 million operations min. Electrical life: 5 A at 250 VAC: 50,000 operations 3 A at 250 VAC: 100,000 operations |
|
Ambient operating temperature | -20 to 60°C (with no condensation or icing) | |
Storage temperature | -25 to 65°C (with no condensation or icing) | |
Ambient operating humidity | 25% to 85% (with no condensation) | |
Storage humidity | 25% to 85% (with no condensation) | |
Altitude | 2,000 m max. | |
Terminal screw tightening torque | 0.49 to 0.59 N·m | |
Terminal wiring method | Recommended wire Solid wire: 2.5 mm2 Twisted wires: AWG16, AWG18 Note: 1. Ferrules with insulating sleeves must be used with twisted wires. 2. Two wires can be twisted together. Recommended ferrules Al 1,5-8BK (for AWG16) manufactured by Phoenix Contact Al 1-8RD (for AWG18) manufactured by Phoenix Contact Al 0,75-8GY (for AWG18) manufactured by Phoenix Contact |
|
Case color | N1.5 | |
Case material | PC and ABS, UL 94 V-0 | |
Weight | Approx. 65 g | |
Mounting | Mounts to DIN Track. | |
Dimensions | 17.5 × 80 × 74 mm (W×D×H) |
Specifications
Input frequency | 50/60 Hz | |
---|---|---|
Overload capacity | Continuous 500 V | |
Repeat accuracy |
Operating value | ±0.5% full scale (at 25°C and 65% humidity, rated power supply voltage, 50/60 Hz sine wave input) |
Operating time | ±50 ms (at 25°C and 65% humidity, rated power supply voltage) | |
Applicable standards |
Conforming standards | EN 60947-5-1 Installation environment (pollution level 2, installation category III) |
EMC | EN 60947-5-1 | |
Safety standards | UL 508 (Recognition), Korean Radio Waves Act (Act 10564), CSA: C22.2 No.14, CCC: GB/T 14048.5 |
|
Insulation resistance | 20 MΩ min. Between external terminals and case Between input terminals and output terminals |
|
Dielectric strength | 2,000 VAC for one minute Between external terminals and case Between input terminals and output terminals |
|
Noise immunity | 1,500 V power supply terminal common/normal mode Square-wave noise of ±1 μs/100 ns pulse width with 1-ns rise time |
|
Vibration resistance | Frequency: 10 to 55 Hz, 0.35-mm single amplitude 10 sweeps of 5 min each in X,Y, and Z directions |
|
Shock resistance | 100 m/s2, 3 times each in 6 directions along 3 axes | |
Degree of protection | Terminals: IP20 |
Relationship of Mounting Distance between K8DS-PZ Relays and Ambient Temperature (Reference Values)
The following diagram shows the relationship between the mounting distances and the ambient temperature.
If the relay is used with an ambient temperature that exceeds these values, the temperature of the K8DS may rise and shorten the life of the internal components.