FX5-CCL-MS
Mô đun CC-link Master
CC-Link IE field network
Model | Master station function | Remote, slave function |
Distance | Compatible CPU module | ||
---|---|---|---|---|---|---|
FX5U | FX5UC | |||||
![]() |
FX5-CCLIEF CC-Link IE field network (Intelligent device station) |
× | ○ | 100 m | *1 ○ Up to 1 module |
*1 *2 ○ Up to 1 module |
*1: Supported in version 1.030 or later.
*2: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
CC-Link
Model | Master station function | Remote, slave function |
Distance | Compatible CPU module | ||
---|---|---|---|---|---|---|
FX5U | FX5UC | |||||
![]() |
FX5-CCL-MS CC-Link system master/intelligent device module |
○ | ○ | 1200 m | ○ | *1 ○ |
![]() |
FX3U-16CCL-M *2 CC-Link (Master station) |
○ | × | 1200 m | *3 ○ Up to 1 module |
*3 ○ Up to 1 module |
![]() |
FX3U-64CCL CC-Link (Intelligent device station) |
× | ○ |
*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.
*2: When CC-Link master and AnyWire Bitty master or AnyWireASLINK master are used together, connect to the front stage (left side) of AnyWire Bitty master and AnyWireASLINK master. When used together, please refer to the FX3U-128ASL-M, FX3U-128BTY-M, and FX3U-16CCL-M user’s manuals.
*3: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.
Ethernet
Model | Data transmission speed |
Maximum segment length |
Supported protocol | No. of connections | |
---|---|---|---|---|---|
![]() |
FX5U CPU module | 100 / 10 Mbps | 100 m (The distance between hub and node) |
・MELSOFT connection ・SLMP (3E frame) ・Socket communication ・Predefined protocol support |
Total of 8 connections for MELSOFT connection, SLMP, socket communication, and Predefined protocol support (Up to 8 external devices are accessible to one CPU module at a time.) |
![]() |
FX5UC CPU module |
Sensor Solution
Model | Transmission protocol | Number of connected I/O points | Compatible CPU module | ||
---|---|---|---|---|---|
FX5U | FX5UC | ||||
![]() |
FX5-ASL-M AnyWireASLINK system master module |
Dedicated protocol (AnyWireASLINK) |
384 points maximum *1 (input: maximum 256 points, output: maximum 256 points) |
○ | *2 ○ |
![]() |
FX3U-128BTY-M *3 AnyWire Bitty series master |
Dedicated protocol (AnyWire Bitty) |
Up to 128 points | *4 ○ Up to 1 module |
*4 ○ Up to 1 module |
![]() |
FX3U-128ASL-M *3 AnyWireASLINK system master |
Dedicated protocol (AnyWireASLINK) |
*1: The number of available remote I/O points per system varies depending on the number of I/O points of the extension devices.
*2: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.
*3: When CC-Link master and AnyWire Bitty master or AnyWireASLINK master are used together, connect to the front stage (left side) of AnyWire Bitty master and AnyWireASLINK master. When used together, please refer to the FX3U-128ASL-M, FX3U-128BTY-M, and FX3U-16CCL-M user’s manuals.
*4: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.
MODBUS communication
Model | Communication interface | Maximum transmission distance | Generic Specifications | Compatible CPU module | ||
---|---|---|---|---|---|---|
FX5U | FX5UC | |||||
![]() |
FX5-232-BD | RS-232C | 15 m | ・Predefined protocol: RTU ・No. of connectable slaves: 1 |
○ Up to 1 modules |
× |
![]() |
FX5-232ADP | ○ Up to 2 modules |
○ Up to 2 modules |
|||
![]() |
FX5U CPU module | RS-485 | 50 m | ・Predefined protocol: RTU ・No. of connectable slaves: 32 |
– | – |
![]() |
FX5UC CPU module | – | – | |||
![]() |
FX5-485-BD | 50 m | ○ Up to 1 module |
× | ||
![]() |
FX5-485ADP | 1200 m | ○ Up to 2 module |
○ Up to 2 module |
Serial communication
Model | Communication interface | Maximum transmission distance | Function type | Compatible CPU module | ||
---|---|---|---|---|---|---|
FX5U | FX5UC | |||||
![]() |
FX5-232-BD | RS-232C | 15 m | ・MELSEC Communication protocol (3C/4C frames) ・Non-protocol communication ・Predefined protocol support |
○ Up to 1 module |
× |
![]() |
FX5-232ADP | ○ Up to 2 module |
○ Up to 2 module |
|||
![]() |
FX5U CPU module | RS-485 | 50 m | ・N:N network ・MELSEC Communication protocol (3C/4C frames) ・Inverter communication ・Non-protocol communication ・Predefined protocol support |
– | – |
![]() |
FX5UC CPU module | – | – | |||
![]() |
FX5-485-BD | 50 m | ○ Up to 1 module |
× | ||
![]() |
FX5-485ADP | 1200 m | ○ Up to 2 module |
○ Up to 2 module |
||
![]() |
FX5-422-BD-GOT | RS-422 | As per GOT specifications | ・GOT connection | ○ Up to 1 module |
– |