FX3G-5DM
Mô đun hiển thị PLC
Display module
During machine setup, adjustment, or program changes,setting and monitoring of timers, counters, and data registers is always required. By using a display module (DM), setting and monitoring of these items can be achieved as reasonable cost.
Model | Applicable FX PLC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
|||||||
![]() |
FX3S-5DM | *6 ○ Max. 1 unit |
× | × | × | × | |||||
![]() |
FX3G-5DM | × | *7 ○ Max. 1 unit |
× | × | × | |||||
![]() |
FX3U-7DM | × | × | ○ Max. 1 unit |
× | *1 ○ Max. 1 unit |
|||||
![]() |
FX3U-7DM-HLD | × | × | ○ | × | *4 ○ |
|||||
![]() |
FX-10DM-SET0 | *5 ○ Max. 1 unit |
*2 ○ Max. 1 unit |
*3 ○ Max. 1 unit |
*2 ○ Max. 1 unit |
*3 ○ Max. 1 unit |
|||||
FX-10DM-E |
*1:Standard equipped on FX3UC-32MT-LT(-2). Cannot be connected to FX3UC-**MT/D(SS) and FX3UC-16MR/D(S)-T.
*2:Limited to the range of FX1N PLC function.
*3:Limited to the range of FX2N PLC function.
*4:Can only be connected to FX3UC-32MT-LT(-2).
*5:Limited to the range of functions that both FX3S PLC and FX1N PLC possess.
*6:Supported by FX3S Ver.1.20 or later.
*7:Supported by FX3G Ver.1.10 or later.
Converter for personal computer connection/interface unit
Conversion interface units for connecting FX series PLC and PC.
Model | Applicable FX PLC | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
Others | |||||||
![]() |
FX-USB-AW | × | × | ○ | × | ○ | FX2N-10GM, FX2N-20GM, FX2N-1RM(-E)-SET |
|||||
![]() |
FX-232AWC-H | ○ | ○ | ○ | ○ | ○ |
RS-422 connection cable for PC
Model | Length | Main purpose | |
---|---|---|---|
![]() |
FX-422CAB0 | 1.5m | Can be combined with FX-232AW(C)(-H) for program transfer. |
![]() |
FX-422CAB | 0.3m | Can be combined with FX-232AW(C)(-H) for program transfer. |
FX-422CAB-150 | 1.5m | ||
FX-422AW0 | 1.5m | For (electrically isolated) connection to RS422 devices such as A6GPP and A7PHP. Cannot be used for PC. |
RS-232C cable for communication
Model | Length | Main purpose | |
---|---|---|---|
![]() |
F2-232CAB-1 | 3.0m | [For DOS/V PC (9Pin)] Can be combined with FX-232AW(C)(-H) for program transfer. |
![]() |
F2-232CAB-2 | 3.0m | [For PC9800 PC(14Pin)] Can be combined with FX-232AW(C)(-H) for program transfer. |
![]() |
F2-232CAB | 3.0m | [For PC (25Pin)] Can be combined with FX-232AW(C)(-H) for program transfer. |
![]() |
FX-232CAB-1 | 3.0m | [For DOS/V PC (9Pin)] Can be combined with PLC RS-232C function expansion board for program transfer. |
![]() |
FX-232CAB-2 | 3.0m | [For PC9800 PC (14Pin)] Can be combined with PLC RS-232C function expansion board for program transfer. |
PLC connection cable for FX-30P
Model | Length | Main purpose | |
---|---|---|---|
![]() |
FX-20P-CAB0 | 1.5m | Can connect to FX0, FX0S, FX1S, FX0N, FX1N, FX2N, FX3S, FX3G, FX3U, FX1NC, FX2NC, FX3GC, FX3UC PLCs. |
![]() |
FX-20P-CAB | 1.5m | Can connect to FX1, FX2, FX2C PLCs. |
![]() |
FX-20P-CADP | 0.3m | Conversion cable to convert FX-20P-CAB (D-sub 25pin) to MINI DIN 8pin for FX0, FX0S, FX1S, FX0N, FX1N, FX2N, FX3S, FX3G, FX3U, FX1NC, FX2NC, FX3GC, FX3UC PLCs. |
Cable (for extended extension)
Model | Length | Main purpose | |
---|---|---|---|
![]() |
FX0N-30EC | 30cm | [Extension cable] Cable for extending extension units.。 Only one cable can be used in a system. Combine with FX2N-CNV-BC connector conversion adapter when extending extension block or special function block. Each extension device includes or is equipped with standard connection cable. |
FX0N-65EC | 65cm |
Extension Module Options
Model | Length | Main purpose | |
---|---|---|---|
![]() |
FX2N-CNV-BC | – | [Connector conversion adapter] Links the connection between extension cable and block side standard cable when extension block or special function block is extended by FX0N-30EC or FX0N-65EC extension cable. (Connection method ⇒ “input/output extension device, terminal block”) |
![]() |
FX2NC-CNV-IF | – | [Conversion adapter] Conversion adapter for connected FX2N extension devices to FX3GC or FX3UC PLCs. |
![]() |
FX3UC-1PS-5V | – | [Extension power supply unit] Adds power when FX3GC or FX3UC series extension power is insufficient. 5V DC 1A |
![]() |
FX3U-1PSU-5V | – | [Extension power supply unit] Adds power when FX3G or FX3U series extension power is insufficient. Internal 5V DC 1A*1 Internal 24V DC 0.3A*1 |
*1:Degrading occurs when the ambient temperature exceeds 40°C.
CF card special adapter
Model | Applicable FX PLC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
FX 3S |
FX 3G |
FX 3U |
FX 3GC |
FX 3UC |
|||||||
![]() |
FX3U-CF-ADP | × | × | ○*1 | × | ○*2 |
*1:Supported by FX3U Ver.2.61 or later. Only 1 unit can be connected to the PLC, and function expansion board is required.
It is treated the same as a communication function expansion board or communication special adapter and occupies one communication channel (ch).
*2:Supported by FX3UC Ver.2.61 or later. Only 1 unit can be connected to the PLC, and function expansion board is required in the case of FX3UC-32MT-LT(-2).
It is treated the same as a communication function expansion board or communication special adapter and occupies one communication channel (ch).
Terminal block
It is possible to change the connector of connector type main unit (FX3GC, FX3UC), extension block, or positioning unit to terminal block.
I/O wiring time can be reduced.
By utilizing terminal blocks with built-in I/O components, it is possible to receive 100V AC inputs or to drive high loads by transistor or relay.
Model | No. of input points |
No. of output points |
Function | |
---|---|---|---|---|
![]() |
FX-16E-TB | up to 16 inputs or 16 outputs | Connects directly to PLC input/output terminals. I/O wiring time can be reduced by using terminals and relaying the wiring of I/O devices located farther from the PLC. |
|
FX-16E-TB/UL | ||||
![]() |
FX-32E-TB | up to 32 inputs or 32 outputs Can be divided into 16 inputs and 16 outputs |
||
FX-32E-TB/UL | ||||
![]() |
FX-16EX-A1-TB | 16 points | – | AC input signal type |
FX-16EX-A1-TB/UL | ||||
![]() |
FX-16EYR-TB | – | 16 points | Relay output type |
FX-16EYR-ES-TB/UL | ||||
FX-16EYS-TB | Triac output type | |||
FX-16EYS-ES-TB/UL | ||||
FX-16EYT-TB | Transistor output type (sink) | |||
FX-16EYT-ES-TB/UL | ||||
FX-16EYT-ESS-TB/UL | Transistor output type (source) |
I/O cable
Model | Length | Main purpose | |
---|---|---|---|
![]() |
FX-16E-500CAB-S | 5m | [General purpose I/O cable] Loose wire with 20 pin connector on one side only |
![]() |
FX-16E-150CAB | 1.5m | [I/O cable for terminal block] Flat cable (with tube) with 20 pin connector on both ends |
FX-16E-300CAB | 3m | ||
FX-16E-500CAB | 5m | ||
![]() |
FX-16E-150CAB-R | 1.5m | [I/O cable for terminal block] Multi-core cable with 20 pin connector on both ends |
FX-16E-300CAB-R | 3m | ||
FX-16E-500CAB-R | 5m | ||
![]() |
FX-32E-150CAB | 1.5m | [I/O cable for terminal block supporting FX2NC-64ET] Flat cable (with tube) with 40 pin connector on FX2NC-64ET side and two 20 pin connectors on terminal block side. |
FX-32E-300CAB | 3m | ||
FX-32E-500CAB | 5m | ||
![]() |
FX-A32E-150CAB | 1.5m | [I/O cable for A6TBXY36 connector/ terminal block conversion unit] |
FX-A32E-300CAB | 3m | ||
FX-A32E-500CAB | 5m |
Connector (for FX3GC, FX3UC connector I/O extension block)
Model | Main purpose | |
---|---|---|
![]() |
FX2C-I/O-CON | [Connector for flat cable] AWG28 (0.1mm2): 10 piece set・Crimp connector: FRC2-A020-3OS 1.27 pitch 20 contacts ・Crimp tool: Requires special arrangement from DDK Ltd. 357J-4674D Press 357J-4664N Attachment |
![]() |
FX2C-I/O-CON-S | [Connector for loose wire] AWG22 (0.3mm2): 5 set・Housing: HU-200S2-001 ・Crimp contact: HU-411S ・Crimp tool: Requires special arrangement from DDK Ltd. 357J-5538 |
FX2C-I/O-CON-SA | [Connector for loose wire] AWG20(0.5mm2): 5 set・Housing: HU-200S2-001 ・Crimp contact: HU-411SA ・Crimp tool: Requires special arrangement from DDK Ltd. 357J-13963 |
|
![]() |
FX-I/O-CON2 | [Connector for flat cable] AWG28 (0.1mm2): 2 piece set・Crimp connector: FRC2-A040-3OS 1.27 pitch 40 contacts ・Crimp tool: Requires special arrangement from DDK Ltd. 357J-4674D Press 357J-4664N Attachment |
![]() |
FX-I/O-CON2-S | [Connector for loose wire] AWG22 (0.3mm2): 2 set・Housing: HU-400S2-001 ・Crimp contact: HU-411S ・Crimp tool: Requires special arrangement from DDK Ltd. 357J-5538 |
FX-I/O-CON2-SA | [Connector for loose wire] AWG20 (0.5mm2): 2 set・Housing: HU-400S2-001 ・Crimp contact: HU-411SA ・Crimp tool: Requires special arrangement from DDK Ltd. 357J-13963 |
Spare parts for FX3GC, FX3UC
Model | Length | Main purpose | |
---|---|---|---|
![]() |
FX2NC-100MPCB | 1m | [Power cable for main unit] Cable for providing 24V DC power to FX3GC, FX3UC main unit (Included with main unit) |
![]() |
FX2NC-100BPCB | 1m | [Power cable for extension input block] Cable for providing 24V DC power to FX2NC input extension block or FX2NC, FX3UC special function block (Included with main unit) |
![]() |
FX2NC-10BPCB1 | 0.1m | [Input power crossover cable for extension input block] Cable for delivering 24V DC input power to multiple FX2NC input extension blocks or FX2NC, FX3UC special function blocks (Included with main unit) |
Simulated input switch
Model | Main purpose | |
---|---|---|
![]() |
FX2C-16SW-C | [Simulation input switch for connector type input] Can be connected to FX3GC, FX3UC series main unit or FX2NC-**EX input connector Includes 0.5m connector cable |
![]() |
FX2C-16SW-TB | [Simluation input switch for FX-16E-TB terminal block] Can only be connected to the lower number 16pt side in the case of FX-32E-TB Cannot be used for AC input |
Expansion board, adapter (Other)
Model | Main purpose | |
---|---|---|
For FX3S | ||
![]() |
FX3S-CNV-ADP | [Adapter for special adapter connection] For connecting FX3 series special adapter (communication, analog) |
For FX3G | ||
![]() |
FX3G-CNV-ADP | [Adapter for special adapter connection] For connecting FX3 series special adapter (communication, analog) |
For FX3S, FX3G | ||
![]() |
FX3G-8AV-BD | [8pt analog volume function expansion board] Adds 8 volume switches in addition to the 2 switches built-in. |
For FX3U, FX3UC-32MT-LT(-2) | ||
![]() |
FX3U-CNV-BD | [Function expand board for special adapter connection] Connector conversion for FX3U-***ADP connection |
![]() |
FX3U-8AV-BD | [8pt analog volume function expansion board] Adds 8 volume switches to the PLC |
Memory cassette, memory board
Model | Main purpose | |
---|---|---|
For FX3S, FX3G | ||
![]() |
FX3G-EEPROM-32L | [EEPROM memory cassette] 32000 step EEPROM memory that PLC can write to and does not require battery backup. (When FX3S is used, 16000 steps can be used.) Function to transfer program between PLC and memory cassette is built-in. Includes protect switch for preventing accidental writing. Convenient for transferring program to multiple PLCs or delivering program to distant places. |
For FX3U, FX3UC | ||
![]() |
FX3U-FLROM-16 | [Flash memory cassette] Flash memory that PLC can write to and does not require battery backup. Includes protect switch for preventing accidental writing. (Maximum 16000 steps) *Supported by FX3UC V2.20 or later |
![]() |
FX3U-FLROM-64 | [Flash memory cassette] Flash memory that PLC can write to and does not require battery backup. Includes protect switch for preventing accidental writing. (Maximum 64000 steps) |
![]() |
FX3U-FLROM-1M | [Flash memory cassette] Flash memory that PLC can write to and does not require battery backup. Includes protect switch for preventing accidental writing. (Maximum 64000 steps) Up to 1.3MB of symbolic information can be stored. *Supported by FX3U, FX3UC Ver.3.00 or later |
![]() |
FX3U-FLROM-64L | [Flash memory cassete with loader function] Flash memory with loader function that PLC can write to and does not require battery backup. Includes protect switch for preventing accidental writing. (Maximum 64000 steps) *Supported by FX3UC V2.20 or later |
Reviews