E32-C11N
Đầu sợi quang giá rẻ Omron
Standard Installation
Threaded Models
Through-beam Fiber Units
Sensing direction (Aperture angle) |
Size | Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | ||||||
Rightangle (Approx. 60°) |
M4 |
![]() IP67 |
Flexible, R1 |
GIGA: 2,000 HS: 700 ST: 1,000 SHS: 280 |
GIGA: 3,000 HS: 1,050 ST: 1,500 SHS: 280 |
1 dia. (5 μm dia./ 2 μm dia.) |
E32-T11N 2M |
Top-view (Approx. 60°) |
![]() IP67 |
E32-T11R 2M | |||||
Top-view (Approx. 15°) |
![]() IP50 |
R25 | GIGA: 4,000 * HS: 2,700 ST: 4,000 * SHS: 1,080 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 1,080 |
2.3 dia. (0.1 dia./ 0.03 dia.) |
E32-LT11 2M | |
Flexible, R1 |
GIGA: 2,000 HS: 2,300 ST: 3,500 SHS: 920 |
GIGA: 4,000 * HS: 3,450 ST: 4,000 * SHS: 920 |
E32-LT11R 2M |
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for E3NX-FA are values for E3NX-FA[] models. The distances for E3NX-FAH[] infrared models
are different.
Reflective Fiber Units
Sensing direction (Aperture angle) |
Size | Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | ||||||
Right-angle (Approx. 60°) |
M3 | Coaxial![]() IP67 |
Flexible, R4 |
GIGA: 110 HS: 46 ST: 50 SHS: 14 |
GIGA: 160 HS: 69 ST: 75 SHS: 14 |
(5 μm dia./ 2 μm dia.) |
E32-C31N 2M |
M6 | Coaxial![]() IP67 |
GIGA: 780 HS: 220 ST: 350 SHS: 100 |
GIGA: 1,170 HS: 340 ST: 520 SHS: 100 |
E32-C91N 2M | |||
Top-view (Approx. 60°) |
M3 | ![]() IP67 |
Flexible, R1 |
GIGA: 140 HS: 40 ST: 60 SHS: 16 |
GIGA: 210 HS: 60 ST: 90 SHS: 16 |
E32-D21R 2M | |
Coaxial![]() IP67 |
R25 | GIGA: 330 HS: 100 ST: 150 SHS: 44 |
GIGA: 490 HS: 150 ST: 220 SHS: 44 |
E32-C31 2M | |||
Coaxial![]() IP67 |
R10 | E32-C31M 1M | |||||
M4 | ![]() IP67 |
Flexible, R1 |
GIGA: 140 HS: 40 ST: 60 SHS: 16 |
GIGA: 210 HS: 60 ST: 90 SHS: 16 |
E32-D211R 2M | ||
M6 | ![]() IP67 |
GIGA: 840 HS: 240 ST: 350 SHS: 100 |
GIGA: 1,260 HS: 360 ST: 520 SHS: 100 |
E32-D11R 2M | |||
Coaxial![]() IP67 |
R25 | GIGA: 1,400 HS: 400 ST: 600 SHS: 180 |
GIGA: 2,100 HS: 600 ST: 900 SHS: 180 |
E32-CC200 2M | |||
Top-view (Approx. 15°) |
M6 | ![]() IP50 |
R25 | GIGA: 860 HS: 250 ST: 360 SHS: 110 |
GIGA: 1,290 HS: 370 ST: 540 SHS: 110 |
(1 dia./ 0.03 dia.) |
E32-LD11 2M |
Flexible, R1 |
GIGA: 840 HS: 240 ST: 350 SHS: 100 |
GIGA: 1,260 HS: 360 ST: 520 SHS: 100 |
E32-LD11R 2M |
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for Reflective Fiber Units are for white paper. (The sensing distance for the E32-LD11 2M/
E32-LD11R 2M are for glossy white paper.)
4. The sensing distances for E3NX-FA are values for E3NX-FA[] models. The distances for E3NX-FAH[] infrared models
are different.
Cylindrical Models
Through-beam Fiber Units
Size | Sensing direction |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | ||||||
1 dia. |
Top-View |
![]() IP67 |
Flexible, R1 |
GIGA: 450 HS: 150 ST: 250 SHS: 60 |
GIGA: 670 HS: 220 ST: 370 SHS: 60 |
0.5 dia. (5 μm dia./ 2 μm dia.) |
E32-T223R 2M |
1.5 dia. |
![]() IP67 |
Bend- resistant, R4 |
GIGA: 680 HS: 220 ST: 400 SHS: 90 |
GIGA: 1,020 HS: 330 ST: 600 SHS: 90 |
E32-T22B 2M | ||
3 dia. |
![]() IP67 |
Flexible, R1 |
GIGA: 2,000 HS: 700 ST: 1,000 SHS: 280 |
GIGA: 3,000 HS: 1,050 ST: 1,500 SHS: 280 |
1 dia. (5 μm dia./ 2 μm dia.) |
E32-T12R 2M | |
Side-View |
![]() IP67 |
GIGA: 750 HS: 260 ST: 450 SHS: 100 |
GIGA: 1,120 HS: 390 ST: 670 SHS: 100 |
E32-T14LR 2M |
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for E3NX-FA are values for E3NX-FA[] models. The distances for E3NX-FAH[] infrared models
are different.
Reflective Fiber Units
Size | Sensing direction |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | ||||||
1.5 dia. | Top-View |
![]() IP67 |
Bend- resistant, R4 |
GIGA: 140 HS: 40 ST: 60 SHS: 16 |
GIGA: 210 HS: 60 ST: 90 SHS: 16 |
(5 μm dia./ 2 μm dia.) |
E32-D22B 2M |
1.5 dia. + 0.5 dia. |
The sleeve cannot be bent. ![]() IP67 |
R4 | GIGA: 28 HS: 8 ST: 12 SHS: 4 |
GIGA: 42 HS: 12 ST: 18 SHS: 4 |
E32-D43M 1M | ||
3 dia. |
![]() IP67 |
Flexible, R1 |
GIGA: 140 HS: 40 ST: 60 SHS: 16 |
GIGA: 210 HS: 60 ST: 90 SHS: 16 |
E32-D22R 2M | ||
![]() IP67 |
Bend- resistant, R4 |
GIGA: 300 HS: 90 ST: 140 SHS: 40 |
GIGA: 450 HS: 130 ST: 210 SHS: 40 |
E32-D221B 2M | |||
Coaxial
![]() IP67 |
R25 | GIGA: 700 HS: 200 ST: 300 SHS: 90 |
GIGA: 1,050 HS: 300 ST: 450 SHS: 90 |
E32-D32L 2M | |||
3 dia. + 0.8 dia. |
The sleeve cannot be bent. ![]() IP67 |
GIGA: 70 HS: 20 ST: 30 SHS: 8 |
GIGA: 100 HS: 30 ST: 45 SHS: 8 |
E32-D33 2M |
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for Reflective Fiber Units are for white paper.
4. The sensing distances for E3NX-FA are values for E3NX-FA[] models. The distances for E3NX-FAH[] infrared models
are different.
Saving Space
Flat Models
Through-beam Fiber Units
Sensing direction |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | |||||
Top-View |
![]() IP67 |
Flexible, R1 |
GIGA: 2,000 HS: 700 ST: 1,000 SHS: 280 |
GIGA: 3,000 HS: 1,050 ST: 1,500 SHS: 280 |
1 dia. (5 μm dia./ 2 μm dia.) |
E32-T15XR 2M |
Side-View |
![]() IP67 |
GIGA: 750 HS: 260 ST: 450 SHS: 100 |
GIGA: 1,120 HS: 390 ST: 670 SHS: 100 |
E32-T15YR 2M | ||
Flat-View |
![]() IP67 |
E32-T15ZR 2M | ||||
![]() IP40 |
GIGA: 2,400 HS: 800 ST: 1,200 SHS: 30 |
GIGA: 3,600 HS: 1,200 ST: 1,800 SHS: 300 |
3 dia. (0.1 dia./ 0.03 dia.) |
E32-LT35Z 2M |
Reflective Fiber Units
Sensing direction |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | |||||
Top-View |
![]() IP67 |
Flexible, R1 |
GIGA: 840 HS: 240 ST: 350 SHS: 100 |
GIGA: 1,260 HS: 360 ST: 520 SHS: 100 |
(5 μm dia./ 2 μm dia.) |
E32-D15XR 2M |
Side-View |
![]() IP67 |
GIGA: 200 HS: 52 ST: 100 SHS: 24 |
GIGA: 300 HS: 78 ST: 150 SHS: 24 |
E32-D15YR 2M | ||
Flat-View |
![]() IP67 |
E32-D15ZR 2M |
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for Reflective Fiber Units are for white paper.
4. The sensing distances for E3NX-FA are values for E3NX-FA[] models. The distances for E3NX-FAH[] infrared models
are different.
Sleeve Models (Close-range Detection)
Through-beam Fiber Units
Sensing direction |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | |||||
Side-View | The sleeve cannot be bent. ![]() IP67 |
Flexible, R1 |
GIGA: 170 HS: 50 ST: 100 SHS: 20 |
GIGA: 250 HS: 75 ST: 150 SHS: 20 |
0.5 dia. (5 μm dia./ 2 μm dia.) |
E32-T24R 2M |
The sleeve cannot be bent. ![]() IP67 |
R10 | GIGA: 450 HS: 150 ST: 250 SHS: 60 |
GIGA: 670 HS: 220 ST: 370 SHS: 60 |
E32-T24E 2M | ||
Top-View | The sleeve cannot be bent. ![]() IP67 |
GIGA: 150 HS: 50 ST: 90 SHS: 20 |
GIGA: 220 HS: 75 ST: 130 SHS: 20 |
0.25 dia. (5 μm dia./ 2 μm dia.) |
E32-T33 1M | |
The sleeve cannot be bent. ![]() IP67 |
GIGA: 510 HS: 170 ST: 300 SHS: 68 |
GIGA: 760 HS: 250 ST: 450 SHS: 68 |
0.5 dia. (5 μm dia./ 2 μm dia.) |
E32-T21-S1 2M | ||
Sleeve bending radius: 5 mm ![]() IP67 |
Flexible, R1 |
GIGA: 2,000 HS: 700 ST: 1,000 SHS: 280 |
GIGA: 3,000 HS: 1,050 ST: 1,500 SHS: 280 |
1 dia. (5 μm dia./ 2 μm dia.) |
E32-TC200BR 2M |
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for E3NX-FA are values for E3NX-FA[] models. The distances for E3NX-FAH[] infrared models
are different.
Reflective Fiber Units
Sensing direction |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | |||||
Side-View | The sleeve cannot be bent ![]() IP67 |
Flexible, R1 |
GIGA: 70 HS: 20 ST: 30 SHS: 8 |
GIGA: 100 HS: 30 ST: 45 SHS: 8 |
(5 μm dia./ 2 μm dia.) |
E32-D24R 2M |
Sleeve bending radius: 25 mm ![]() IP67 |
R25 | GIGA: 120 HS: 45 ST: 53 SHS: 14 |
GIGA: 180 HS: 67 ST: 79 SHS: 14 |
E32-D24-S2 2M | ||
Top-View | The sleeve cannot be bent. ![]() IP67 |
R4 | GIGA: 28 HS: 8 ST: 12 SHS: 4 |
GIGA: 42 HS: 12 ST: 18 SHS: 4 |
E32-D43M 1M | |
The sleeve cannot be bent. ![]() IP67 |
GIGA: 14 HS: 4 ST: 6 SHS: 2 |
GIGA: 21 HS: 6 ST: 9 SHS: 2 |
E32-D331 2M | |||
The sleeve cannot be bent. ![]() IP67 |
R25 | GIGA: 70 HS: 20 ST: 30 SHS: 8 |
GIGA: 100 HS: 30 ST: 45 SHS: 8 |
E32-D33 2M | ||
The sleeve cannot be bent. ![]() IP67 |
R4 | GIGA: 63 HS: 18 ST: 27 SHS: 7 |
GIGA: 94 HS: 27 ST: 40 SHS: 7 |
E32-D32-S1 0.5M | ||
The sleeve cannot be bent. ![]() IP67 |
E32-D31-S1 0.5M | |||||
Sleeve bending radius: 5 mm ![]() IP67 |
Flexible, R1 |
GIGA: 140 HS: 40 ST: 60 SHS: 16 |
GIGA: 210 HS: 60 ST: 90 SHS: 16 |
E32-DC200F4R 2M | ||
The sleeve cannot be bent. ![]() IP67 |
R10 | GIGA: 250 HS: 72 ST: 110 SHS: 30 |
GIGA: 370 HS: 100 ST: 160 SHS: 30 |
E32-D22-S1 2M | ||
Sleeve bending radius: 10 mm ![]() IP67 |
E32-D21-S3 2M | |||||
The sleeve cannot be bent. ![]() IP67 |
Flexible, R1 |
GIGA: 840 HS: 240 ST: 350 SHS: 100 |
GIGA: 1,260 HS: 360 ST: 520 SHS: 100 |
E32-DC200BR 2M | ||
Sleeve bending radius: 10 mm ![]() IP67 |
R10 | GIGA: 250 HS: 72 ST: 110 SHS: 30 |
GIGA: 370 HS: 100 ST: 160 SHS: 30 |
E32-D25-S3 2M |
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for Reflective Fiber Units are for white paper.
4. The sensing distances for E3NX-FA are values for E3NX-FA[] models. The distances for E3NX-FAH[] infrared models
are different.
Beam Improvements
Small-Spot, Reflective (Minute Object Detection)
Reflective Fiber Units
Variable-spot types
Lens Units + Fiber Unit
Type | Spot diameter |
Center distance (mm) |
Lens Units | Lens Units + Fiber Units | Fiber Unit | |
---|---|---|---|---|---|---|
Models | Appearance (mm) | Bending radius of cable |
Model | |||
Variable spot |
0.1 to 0.6 dia. | 6 to 15 | E39-F3A |
![]() |
R25 | E32-C42 1M |
0.3 to 1.6 dia. | 10 to 30 | E39-F17 |
![]() |
Parallel-light-spot types
Lens Unit + Fiber Units
Type | Spot diameter |
Center distance (mm) |
Lens Units | Lens Units + Fiber Units | Fiber Unit | |
---|---|---|---|---|---|---|
Models | Appearance (mm) | Bending radius of cable |
Model | |||
Parallel light |
4 dia. | 0 to 20 | E39-F3C |
![]() |
R25 | E32-C31 2M |
![]() |
Flexible, R2 | E32-C21N 2M |
Small-spot types
Integrated Lens
Type | Spot diameter |
Center distance (mm) |
Appearance (mm) | Bending radius of cable |
Models |
---|---|---|---|---|---|
Short-distance, Small-spot |
0.1 dia. | 5 |
![]() Lens: unnecessary |
R25 | E32-C42S 1M |
Long-distance, Small-spot |
6 dia. | 50 |
![]() Lens: unnecessary |
E32-L15 2M |
for E3NX-FAH[] infrared models varies.
Small-spot Models
Lens Units + Fiber Units
Type | Spot diameter |
Center distance (mm) |
Lens Units | Lens Units + Fiber Units | Fiber Unit | |
---|---|---|---|---|---|---|
Models | Appearance (mm) | Bending radius of cable |
Models | |||
Short- distance, small-spot |
0.1 dia. | 7 | E39-F3A-5 | ![]() |
R25 | E32-C41 1M |
0.5 dia. | ![]() |
E32-C31 2M | ||||
![]() |
Flexible, R2 | E32-C21N 2M | ||||
Medium- distance, small-spot |
0.2 dia. | 17 | E39-F3B | ![]() |
R25 | E32-C41 1M |
0.5 dia. | ![]() |
E32-C31 2M | ||||
![]() |
Flexible, R2 | E32-C21N 2M | ||||
Long- distance, small-spot |
3 dia. | 50 | E39-F18 | ![]() |
R25 | E32-CC200 2M |
![]() |
Flexible, R4 | E32-C91N 2M |
for E3NX-FAH[] infrared models varies.
High-power Beam (Long-distance Installation, Dust-resistant)
Fiber only
Through-beam Fiber Units
Sensing direction |
Aperture angle |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | ||||||
Right- angle |
15° | ![]() IP50 |
Flexible, R2 |
GIGA: 4,000 *1 HS: 2,300 ST: 3,500 SHS: 920 |
GIGA: 4,000 *1 HS: 3,450 ST: 4,000 *1 SHS: 920 |
2.3 dia. (0.1 dia./ 0.03 dia.) |
E32-LT11N 2M |
Top- View |
10° | ![]() IP67 |
R25 | GIGA: 20,000 *2 HS: 20,000 *2 ST: 20,000 *2 SHS: 8,000 |
GIGA: 20,000 *2 HS: 20,000 *2 ST: 20,000 *2 SHS: 8,000 |
10 dia. | E32-T17L 10M |
15° | ![]() IP50 |
GIGA: 4,000 *1 HS: 2,700 ST: 4,000 *1 SHS: 1,080 |
GIGA: 4,000 *1 HS: 4,000 *1 ST: 4,000 *1 SHS: 1,080 |
2.3 dia. (0.1 dia./ 0.03 dia.) |
E32-LT11 2M | ||
Flexible, R1 |
GIGA: 4,000 *1 HS: 2,300 ST: 3,500 SHS: 920 |
GIGA: 4,000 *1 HS: 3,450 ST: 4,000 *1 SHS: 920 |
E32-LT11R 2M | ||||
Side- View |
30° | ![]() IP67 |
R25 | GIGA: 4,000 *1 HS: 4,000 *1 ST: 4,000 *1 SHS: 1,800 |
GIGA: 4,000 *1 HS: 4,000 *1 ST: 4,000 *1 SHS: 1,800 |
4 dia. (0.1 dia./ 0.03 dia.) |
E32-T14 2M |
*2. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Note. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Reflective Fiber Units
Sensing direction |
Aperture angle |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | ||||||
Top-View | 4° |
![]() IP40 |
Bend- resistant, R4 |
GIGA: 40 to 2,800 HS: 40 to 900 ST: 40 to 1,400 SHS: 40 to 480 |
GIGA: 40 to 4,000 *2 HS: 40 to 1,350 ST: 40 to 2,100 SHS: 40 to 480 |
– | E32-D16 2M |
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for Reflective Fiber Units are for white paper.
4. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Lens (to 70°C)
Through-beam Fiber Units
Lens Units | Type | High-power (incident level: 50 times) |
Ultra-high-power (incident level: 160 times) |
Side-View (incident level: 0.8 times) |
|||
---|---|---|---|---|---|---|---|
Models | E39-F1 | E39-F16 | E39-F2 | ||||
Appearance |
![]() |
![]() |
![]() |
||||
Aperture angle | Approx. 12° | Approx. 6° | Approx. 60° | ||||
Fiber Units | Optical axis diameter (minimum sensing object) |
4 dia. (0.1 dia.) | 7.2 dia. | 3 dia. (0.1 dia.) | |||
Models | Appearance (mm) |
Sensing distance (mm) | |||||
E3X-HD | E3NX-FA | E3X-HD | E3NX-FA | E3X-HD | E3NX-FA | ||
E32-T11N 2M |
![]() |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 2,000 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 2,000 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 3,600 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 3,600 |
– | – |
E32-T11R 2M |
![]() |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 2,000 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 2,000 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 3,600 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 3,600 |
GIGA: 1,450 HS: 500 ST: 800 SHS: 200 |
GIGA: 2,170 HS: 750 ST: 1,200 SHS: 200 |
E32-T11 2M |
![]() |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 1,860 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 1,860 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 4,000 * |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 4,000 * |
GIGA: 2,300 HS: 860 ST: 1,320 SHS: 320 |
GIGA: 3,450 HS: 1,290 ST: 1,980 SHS: 320 |
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Through-beam Fiber Units (Heat-resistant)
Lens Units | Type | High-power (incident level: 50 times) |
Ultra-high-power (incident level: 160 times) |
Side-View (incident level: 0.8 times) |
|||
---|---|---|---|---|---|---|---|
Models | E39-F1 | E39-F16 | E39-F2 | ||||
Appearance |
![]() |
![]() |
![]() |
||||
Aperture angle | Approx. 12° | Approx. 6° | Approx. 60° | ||||
Fiber Units | Optical axis diameter (minimum sensing object) |
4 dia. (0.1 dia.) | 7.2 dia. | 3 dia. (0.1 dia.) | |||
Models | Appearance (mm) | Sensing distance (mm) | |||||
E3X-HD | E3NX-FA | E3X-HD | E3NX-FA | E3X-HD | E3NX-FA | ||
E32-T51R 2M | Heat-resistant up to 100°C ![]() |
GIGA: 4,000 * HS: 3,900 ST: 4,000 * SHS: 1,500 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 1,500 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 4,000 * |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 4,000 * |
GIGA: 1,400 HS: 500 ST: 720 SHS: 200 |
GIGA: 2,100 HS: 750 ST: 1,080 SHS: 200 |
E32-T81R-S 2M | Heat-resistant up to 200°C ![]() |
GIGA: 4,000 * HS: 2,700 ST: 4,000 * SHS: 1,000 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 1,000 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 1,800 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 1,800 |
GIGA: 1,000 HS: 360 ST: 550 SHS: 140 |
GIGA: 1,500 HS: 540 ST: 820 SHS: 140 |
E32-T61-S 2M | Heat-resistant up to 350°C (200°C) (See Note 3) ![]() |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 1,800 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 1,800 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 3,100 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 3,100 |
GIGA: 1,680 HS: 600 ST: 900 SHS: 240 |
GIGA: 2,520 HS: 900 ST: 1,350 SHS: 240 |
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The ambient temperature of E32-T61-S must be between −40 to 200°C when using it with E39-F1 or E39-F2 Lens
Unit.
The ambient temperature of E32-T61-S must be between −40 to 350°C when using it with E39-F16 Lens Unit.
4. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Lens Units | Type | High-power (incident level: 50 times) |
Ultra-high-power (incident level: 160 times) |
||
---|---|---|---|---|---|
Models | E39-F1-33 | E39-F16 | |||
Appearance |
![]() |
![]() |
|||
Aperture angle | Approx. 12° | Approx. 6° | |||
Fiber Units | Optical axis diameter (minimum sensing object) |
4 dia. (0.1 dia.) | 7.2 dia. | ||
Models | Appearance (mm) | Sensing distance (mm) | |||
E3X-HD | E3NX-FA | E3X-HD | E3NX-FA | ||
E32-T51 2M | Heat-resistant up to 150°C
![]() |
GIGA: 4,000 * HS: 2,300 ST: 4,000 * SHS: 1,400 |
GIGA: 4,000 * HS: 3,450 ST: 4,000 * SHS: 1,400 |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 4,000 * |
GIGA: 4,000 * HS: 4,000 * ST: 4,000 * SHS: 4,000 * |
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Narrow View (Detection Across clearance)
Through-beam Fiber Units
Sensing direction |
Aperture angle |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | ||||||
Side-View | 1.5° |
![]() Thickness: 3 mm |
Flexible, R1 |
GIGA: 3,220 HS: 1,200 ST: 1,780 SHS: 500 |
GIGA: 4,000 * HS: 1,800 ST: 2,670 SHS: 500 |
2 dia. (0.1 dia./ 0.03 dia.) |
E32-A03 2M |
![]() Thickness: 3 mm |
R10 | E32-A03-1 2M | |||||
3.4° |
![]() Thickness: 2 mm |
GIGA: 1,280 HS: 450 ST: 680 SHS: 200 |
GIGA: 1,920 HS: 670 ST: 1,020 SHS: 200 |
1.2 dia. (0.1 dia./ 0.03 dia.) |
E32-A04 2M | ||
4° |
![]() IP50 |
Flexible, R1 |
GIGA: 4,000 * HS: 1,460 ST: 2,200 SHS: 580 |
GIGA: 4,000 * HS: 2,190 ST: 3,300 SHS: 580 |
2 dia. (0.1 dia./ 0.03 dia.) |
E32-T24SR 2M | |
R10 | GIGA: 4,000 * HS: 1,740 ST: 2,600 SHS: 700 |
GIGA: 4,000 * HS: 2,610 ST: 3,900 SHS: 700 |
E32-T24S 2M | ||||
Top-View |
![]() IP50 |
GIGA: 4,000 * HS: 2,500 ST: 3,800 SHS: 1,000 |
GIGA: 4,000 * HS: 3,750 ST: 4,000 * SHS: 1,000 |
1.7 dia. (0.1 dia./ 0.03 dia.) |
E32-T22S 2M |
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Detection without Background Interference
Limited-reflective Fiber Units
Sensing direction |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Standard sensing object (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | |||||
Flat-View |
![]() IP40 |
R25 | GIGA: 0 to 15 HS: 0 to 15 ST: 0 to 15 SHS: 0 to 12 |
GIGA: 0 to 15 HS: 0 to 15 ST: 0 to 15 SHS: 0 to 12 |
Soda glass with reflection factor of 7% |
E32-L16-N 2M |
![]() IP50 |
R10 | GIGA: 0 to 4 HS: 0 to 4 ST: 0 to 4 SHS: 0 to 4 |
GIGA: 0 to 4 HS: 0 to 4 ST: 0 to 4 SHS: 0 to 4 |
(5 μm dia./ 2 μm dia.) |
E32-L24S 2M | |
Side-View |
![]() IP50 |
GIGA: 5.4 to 9 HS: 5.4 to 9 ST: 5.4 to 9 SHS: 5.4 to 9 (Center 7.2) |
GIGA: 5.4 to 9 HS: 5.4 to 9 ST: 5.4 to 9 SHS: 5.4 to 9 (Center 7.2) |
E32-L25L 2M |
light level.
2. The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
3. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
4. The sensing distances for Reflective Fiber Units are for white paper.
5. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Transparent Object Detection
Retro-reflective
Retro-reflective Fiber Units (With M.S.R. Function)
Type | Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | ||
---|---|---|---|---|---|---|---|
Features | Size | E3X-HD | E3NX-FA | ||||
Film detection * |
M6 | ![]() IP50 |
Flexible, R2 |
GIGA: 1,350 HS: 1,000 ST: 1,200 SHS: 550 |
GIGA: 2,020 HS: 1,500 ST: 1,800 SHS: 550 |
– | E32-LR11NP 2M + E39-RP1 |
Square | – | ![]() IP66 |
R25 | GIGA: 150 to 1,500 HS: 150 to 1,500 ST: 150 to 1,500 SHS: 150 to 1,500 |
GIGA: 150 to 1,500 HS: 150 to 1,500 ST: 150 to 1,500 SHS: 150 to 1,500 |
(0.2 dia./ 0.07 dia.) |
E32-R16 2M |
Threaded Models |
M6 | ![]() IP67 |
R10 | GIGA: 10 to 250 HS: 10 to 250 ST: 10 to 250 SHS: 10 to 250 |
GIGA: 10 to 370 HS: 10 to 370 ST: 10 to 370 SHS: 10 to 250 |
(0.1 dia./ 0.03 dia.) |
E32-R21 2M |
Lens Unit. Check suitability beforehand.
Note 1. Objects with a high reflection factor may cause the Fiber Sensor to detect reflected light as incident light. Also,
stable detection may not be possible for transparent objects.
Check suitability beforehand.
2. The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
3. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
4. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Limited-reflective (Glass Detection)
Limited-reflective Fiber Units
Type | Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Standard sensing object (minimum sensing object) |
Models | ||
---|---|---|---|---|---|---|---|
Features | Sensing direction |
E3X-HD | E3NX-FA | ||||
Small size |
Flat- View |
![]() IP50 |
R10 | GIGA: 0 to 4 HS: 0 to 4 ST: 0 to 4 SHS: 0 to 4 |
GIGA: 0 to 4 HS: 0 to 4 ST: 0 to 4 SHS: 0 to 4 |
(5 μm dia./ 2 μm dia.) |
E32-L24S 2M |
Standard |
![]() IP40 |
R25 | GIGA: 0 to 15 HS: 0 to 15 ST: 0 to 15 SHS: 0 to 12 |
GIGA: 0 to 15 HS: 0 to 15 ST: 0 to 15 SHS: 0 to 12 |
Soda glass with reflection factor of 7% |
E32-L16-N 2M | |
Glass- substrate alignment, 70°C |
![]() IP40 |
GIGA: 10 to 20 HS: 10 to 20 ST: 10 to 20 SHS: – |
GIGA: 10 to 20 HS: 10 to 20 ST: 10 to 20 SHS: – |
E32-A08 2M * | |||
Standard long distance |
![]() IP40 |
GIGA: 12 to 30 HS: 12 to 30 ST: 12 to 30 SHS: – |
GIGA: 12 to 30 HS: 12 to 30 ST: 12 to 30 SHS: – |
E32-A12 2M | |||
Side View form |
Side- View |
![]() IP50 |
R10 | GIGA: 5.4 to 9 HS: 5.4 to 9 ST: 5.4 to 9 SHS: 5.4 to 9 (Center 7.2) |
GIGA: 5.4 to 9 HS: 5.4 to 9 ST: 5.4 to 9 SHS: 5.4 to 9 (Center 7.2) |
(5 μm dia./ 2 μm dia.) |
E32-L25L 2M |
Glass- substrate Mapping, 70°C |
Top- View |
![]() IP40 |
R25 | GIGA: 15 to 38 HS: 15 to 38 ST: 15 to 38 SHS: – (Center 25) |
GIGA: 15 to 38 HS: 15 to 38 ST: 15 to 38 SHS: – (Center 25) |
End surface of soda glass with reflection factor of 7% (t = 0.7 mm, rounded edges) |
E32-A09 2M |
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for Reflective Fiber Units are for white paper.
4. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Environmental Immunity
Chemical-resistant, Oil-resistant
Through-beam Fiber Units
Type | Sensing direction |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | ||||||
Oil- resistant |
Right- Angle |
![]() IP68 |
Flexible, R1 |
GIGA: 4,000 *1 HS: 4,000 *1 ST: 4,000 *1 SHS: 2,200 |
GIGA: 4,000 *1 HS: 4,000 *1 ST: 4,000 *1 SHS: 2,200 |
4 dia. (0.1 dia./ 0.03 dia.) |
E32-T11NF 2M |
![]() IP68G |
Flexible, R1 |
GIGA: 2,200 HS: 730 ST: 1,100 SHS: 270 |
GIGA: 3,300 HS: 1,100 ST: 1,600 SHS: 270 |
2 dia. (0.1 dia./ 0.03 dia.) |
E32-T11NFS 2M | ||
Chemical/ oil resistant |
Top- View |
![]() IP67 |
R40 | GIGA: 4,000 *1 HS: 4,000 *1 ST: 4,000 *1 SHS: 1,600 |
GIGA: 4,000 *1 HS: 4,000 *1 ST: 4,000 *1 SHS: 1,600 |
4 dia. (0.1 dia./ 0.03 dia.) |
E32-T12F 2M |
![]() IP67 |
R4 | GIGA: 4,000 *1 HS: 2,600 ST: 4,000 *1 SHS: 1,000 |
GIGA: 4,000 *1 HS: 3,900 ST: 4,000 *1 SHS: 1,000 |
E32-T11F 2M | |||
Side- view |
![]() IP67 |
R40 | GIGA: 1,400 HS: 500 ST: 800 SHS: 200 |
GIGA: 2,100 HS: 750 ST: 1,200 SHS: 200 |
3 dia. (0.1 dia./ 0.03 dia.) |
E32-T14F 2M | |
Chemical/ oil resistant 150°C *2 |
Top- View |
![]() IP67 |
GIGA: 4,000 *1 HS: 1,800 ST: 2,800 SHS: 700 |
GIGA: 4,000 *1 HS: 2,700 ST: 4,000 *1 SHS: 700 |
4 dia. (0.1 dia./ 0.03 dia.) |
E32-T51F 2M |
*2. For continuous operation, use the Fiber Unit between -40 and 130°C.
*3. The IP68G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards).
The IP68 indicates the same level of protection as defined by the IEC, and the G indicates that a device has
resistance to oil. Passed OMRON’s Oil-resistant Component Evaluation Standards (OMRON’s own durability
evaluation standards)
(Cutting oil type: specified in JIS K 2241:2000; Temperature: 35°C max.)
Note. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Reflective Fiber Units
Type | Sensing direction |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Standard sensing object (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | ||||||
Semiconductors: Cleaning, developing, and etching, 60°C |
Top- View |
![]() IP67 |
R40 | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm) 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) |
Glass (t=0.7 mm) |
E32-L11FP 2M | |
Semiconductors: Resist stripping, 85°C |
![]() IP67 |
8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm) 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) |
E32-L11FS 2M | ||||
Chemical/ oil resistant |
![]() IP67 |
GIGA: – HS: 130 ST: 190 SHS: 60 |
GIGA: – HS: 190 ST: 280 SHS: 60 |
(5 μm dia./ 2 μm dia.) |
E32-D12F 2M | ||
Only cable: chemical resistant |
![]() IP67 |
R4 | GIGA: 840 HS: 240 ST: 350 SHS: 100 |
GIGA: 1,260 HS: 360 ST: 520 SHS: 100 |
E32-D11U 2M |
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for Reflective Fiber Units are for white paper.
4. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Bending-resistant, Disconnection-resistant
Through-beam Fiber Units
Size | Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | |||||
1.5 dia. |
![]() IP67 |
Bend-resistant, R4 |
GIGA: 680 HS: 220 ST: 400 SHS: 90 |
GIGA: 1,020 HS: 330 ST: 600 SHS: 90 |
0.5 dia. (5 μm dia./ 2 μm dia.) |
E32-T22B 2M |
M3 |
![]() IP67 |
E32-T21 2M | ||||
M4 |
![]() IP67 |
GIGA: 2,500 HS: 900 ST: 1,350 SHS: 360 |
GIGA: 3,750 HS: 1,350 ST: 2,020 SHS: 360 |
1 dia. (5 μm dia./ 2 μm dia.) |
E32-T11 2M | |
Square |
![]() IP67 |
GIGA: 500 HS: 170 ST: 300 SHS: 70 |
GIGA: 750 HS: 250 ST: 450 SHS: 70 |
0.5 dia. (5 μm dia./ 2 μm dia.) |
E32-T25XB 2M |
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Protective Stainless Spiral Tube (Sold separately)
Insert the fiber cable into the protective tube to prevent breaking by snagging or shock.
Applicable Fiber Units | Model | Quantity |
---|---|---|
E32-T11R 2M/E32-T11 2M/E32-LT11 2M/E32-LT11R 2M/ E32-T51R 2M/E32-T51 2M |
E39-F32C 1M | 2 pieces |
* This Tube cannot be used if a Lens Unit is being used.
Reflective Fiber Units
Size | Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | |||||
1.5 dia. |
![]() IP67 |
Bend-resistant, R4 |
GIGA: 140 HS: 40 ST: 60 SHS: 16 |
GIGA: 210 HS: 60 ST: 90 SHS: 16 |
(5 μm dia./ 2 μm dia.) |
E32-D22B 2M |
M3 |
![]() IP67 |
E32-D21 2M | ||||
3 dia. |
![]() IP67 |
GIGA: 300 HS: 90 ST: 140 SHS: 40 |
GIGA: 450 HS: 130 ST: 210 SHS: 40 |
E32-D221B 2M | ||
M4 |
![]() IP67 |
E32-D21B 2M | ||||
M6 |
![]() IP67 |
GIGA: 840 HS: 240 ST: 350 SHS: 100 |
GIGA: 1,260 HS: 360 ST: 520 SHS: 100 |
E32-D11 2M | ||
Square |
![]() IP67 |
GIGA: 240 HS: 60 ST: 100 SHS: 30 |
GIGA: 360 HS: 90 ST: 150 SHS: 30 |
E32-D25XB 2M |
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
3. The first value is for the E3X-HD and the second value is for the E3NX-FA.
The sensing distances for Reflective Fiber Units are for white paper.
4. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Protective Stainless Spiral Tube (Sold separately)
Insert the fiber cable into the protective tube to prevent breaking by snagging or shock.
Applicable Fiber Units | Models | Quantity |
---|---|---|
E32-D21R 2M/E32-C31 2M/E32-D21 2M | E39-F32A 1M | 1 piece |
E32-D211R 2M/E32-D21B 2M | E39-F32C 1M | 2 pieces |
E32-D11R 2M/E32-CC200 2M/E32-D11 2M/E32-D51R 2M/E32-D51 2M | E39-F32D 1M | 1 piece |
* This Tube cannot be used if a Lens Unit is being used.
Heat-resistant
Through-beam Fiber Units
Heat- resistant temperature |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | |||||
100℃ *1 |
![]() IP50 |
Flexible, R2 |
GIGA: 1,600 HS: 560 ST: 800 SHS: 225 |
GIGA: 2,400 HS: 840 ST: 1,200 SHS: 225 |
1 dia. (0.1 dia./ 0.03 dia.) |
E32-T51R 2M |
150℃ *2 |
![]() IP67 |
R35 | GIGA: 2,800 HS: 1,000 ST: 1,500 SHS: 400 |
GIGA: 4,000 *5 HS: 1,500 ST: 2,250 SHS: 400 |
1.5 dia. (0.1 dia./ 0.03 dia.) |
E32-T51 2M |
200℃ *3 |
![]() IP67 |
R10 | GIGA: 1,000 HS: 360 ST: 550 SHS: 140 |
GIGA: 1,500 HS: 540 ST: 820 SHS: 140 |
0.7 dia. (5 μm dia./ 2 μm dia.) |
E32-T81R-S 2M |
350℃ *4 |
![]() IP67 |
R25 | GIGA: 1,680 HS: 600 ST: 900 SHS: 240 |
GIGA: 2,520 HS: 900 ST: 1,350 SHS: 240 |
1 dia. (5 μm dia./ 2 μm dia.) |
E32-T61-S 2M |
70℃ | – | Standard Fiber Units can be used. |
*2 For continuous operation, use the Fiber Unit between −40 to 130°C.
*3 The heat-resistant rating is not the same for all parts of the Fiber Unit. Refer to the dimensions diagrams for details.
*4 The ambient operating temperature for the E32-T61-S 2M is −60 to 350°C.
*5 The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Reflective Fiber Units
Heat- resistant temperature |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Standard sensing object (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | |||||
100℃ *1 |
![]() IP50 |
Flexible, R2 |
GIGA: 670 HS: 190 ST: 280 SHS: 80 |
GIGA: 1,000 HS: 280 ST: 420 SHS: 80 |
(5 μm dia./ 2 μm dia.) |
E32-D51R 2M |
150℃ *2 |
![]() IP67 |
R35 | GIGA: 1,120 HS: 320 ST: 450 SHS: 144 |
GIGA: 1,680 HS: 480 ST: 670 SHS: 144 |
E32-D51 2M | |
200℃ *3 |
![]() IP67 |
R10 | GIGA: 420 HS: 120 ST: 180 SHS: 54 |
GIGA: 630 HS: 180 ST: 270 SHS: 54 |
E32-D81R-S 2M | |
300℃ |
![]() IP30 |
R25 | GIGA: 10 to 20 HS: 10 to 20 ST: 10 to 20 SHS: – |
GIGA: 10 to 20 HS: 10 to 20 ST: 10 to 20 SHS: – |
Soda glass with reflection factor of 7% |
E32-A08H2 2M |
![]() IP40 |
GIGA: 20 to 30 HS: 20 to 30 ST: 20 to 30 SHS: – |
GIGA: 20 to 30 HS: 20 to 30 ST: 20 to 30 SHS: – |
End surface of soda glass with eflection factor of 7% (t = 0.7 mm, rounded edges) |
E32-A09H2 2M | ||
350℃ *3 |
![]() IP67 |
GIGA: 420 HS: 120 ST: 180 SHS: 54 |
GIGA: 630 HS: 180 ST: 270 SHS: 54 |
(5 μm dia./ 2 μm dia.) |
E32-D611-S 2M | |
![]() |
GIGA: 420 HS: 120 ST: 180 SHS: 54 |
GIGA: 630 HS: 180 ST: 270 SHS: 54 |
E32-D61-S 2M | |||
400℃ *3 | Sleeve bending radius : 10 mm ![]() |
GIGA: 280 HS: 80 ST: 120 SHS: 36 |
GIGA: 420 HS: 120 ST: 180 SHS: 36 |
E32-D73-S 2M | ||
70℃ | – | Standard Fiber Units can be used. |
*2 For continuous operation, use the Fiber Unit between −40 to 130°C.
*3 The heat-resistant rating is not the same for all parts of the Fiber Unit. Refer to the dimensions diagrams for details.
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for Reflective Fiber Units are for white paper.
4. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Special Applications
Area Beam (Area Detection)
Through-beam Fiber Units
Type | Sensing width |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | ||||||
Area | 11 mm | ![]() IP50 |
Flexible, R1 |
GIGA: 3,100 HS: 1,120 ST: 1,700 SHS: 440 |
GIGA: 4,000 *1 HS: 1,680 ST: 2,550 SHS: 440 |
(0.2 dia./ 0.07 dia.) *2 |
E32-T16PR 2M |
![]() IP50 |
GIGA: 2,750 HS: 960 ST: 1,500 SHS: 380 |
GIGA: 4,000 *1 HS: 1,440 ST: 2,250 SHS: 380 |
E32-T16JR 2M | ||||
30 mm | ![]() IP50 |
GIGA: 4,000 *1 HS: 1,700 ST: 2,600 SHS: 680 |
GIGA: 4,000 *1 HS: 2,550 ST: 3,900 SHS: 680 |
(0.3 dia./ 0.1 dia.) *2 |
E32-T16WR 2M | ||
Array | 10 mm | ![]() IP50 |
R5 | GIGA: 10 HS: 10 ST: 10 SHS: 10 |
GIGA: 10 HS: 10 ST: 10 SHS: 10 |
11 dia. | E32-G16 2M |
*2. The values for the minimum sensing object were obtained for detection in the sensing area with the sensing distance
set to 300 mm.
(The values are for a stationary sensing object.)
The first value is for the E3X-HD and the second value is for the E3NX-FA.
Note. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Reflective Fiber Units
Type | Sensing width |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | ||||||
Array | 11 mm |
![]() IP67 |
Bend- resistant, R4 |
GIGA: 700 HS: 200 ST: 300 SHS: 90 |
GIGA: 1,050 HS: 300 ST: 450 SHS: 90 |
(5 μm dia./ 2 μm dia.) |
E32-D36P1 2M |
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Liquid-level Detection
Detection scheme |
Tube diameter |
Features | Appearance (mm) |
Bending radius of cable |
Applicable range | Optical axis diameter (minimum sensing object) |
Models |
---|---|---|---|---|---|---|---|
Tube- mounting |
3.2, 6.4 and 9.5 dia. |
Resistant to bubbles and droplets Residual quantity detection |
![]() IP50 |
Bend- resistant, R4 |
Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 dia. and a recommended wall thickness of 1 mm |
– | E32-A01 5M |
8 to 10 dia. |
Ideal for mounting at multilevels |
![]() IP50 |
R10 | Applicable tube: Transparent tube with a diameter of 8 to 10 dia. and a recommended wall thickness of 1 mm |
– | E32-L25T 2M | |
No restric- tions |
Usable on large diameter tubes Resistant to bubbles and droplets |
![]() IP67 |
R4 | Applicable tube: Transparent tube (no restrictions on diameter) |
– | E32-D36T 2M | |
Liquid contact (heat- resistant up to 200°C) |
– | – |
![]() IP68 |
R40 R25 *3 |
Liquid-contact Type *1 |
– | E32-D82F1 4M |
*2. The applicable range is the same whether an E3X-HD series or E3NX-FA series is used. This does not include E3NX-
FAH[] infrared models varies.
When using a Fiber Amplifier Unit in giga-power mode, level detection may not work depending on the tube diameter.
Make sure to confirm operation with the actual tube.
*3. The bending radius of the sensing section (except for the unbendable section) is 40 mm, and the bending radius of
the fiber is 25 mm.
Vacuum-resistant
Through-beam Fiber Units
Type | Heat- resistant temperature |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | ||||||
Vacuum side |
120℃ |
![]() |
R30 | GIGA: 720 HS: 260 ST: 400 SHS: 100 |
GIGA: 1,080 HS: 390 ST: 600 SHS: 100 |
1.2 dia. (10 μm dia./ 4 μm dia.) |
E32-T51V 1M |
![]() |
GIGA: 2,000 * HS: 1,360 ST: 2,000 SHS: 520 |
GIGA: 2,000 * HS: 2,000 * ST: 2,000 * SHS: 520 |
4 dia. (0.1 dia./ 0.03 dia.) |
E32-T51V 1M + E39-F1V |
|||
200℃ |
![]() |
R25 | GIGA: 1,760 HS: 640 ST: 950 SHS: 260 |
GIGA: 2,000 * HS: 960 ST: 1,420 SHS: 260 |
2 dia. (0.1 dia./ 0.03 dia.) |
E32-T84SV 1M | |
Atmospheric pressure side |
70℃ |
![]() |
– | – | – | E32-T10V 2M |
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Flange
Appearance | Type | Models |
---|---|---|
![]() |
4-channel flange | E32-VF4 |
![]() |
1-channel flange | E32-VF1 |
FPD, Semiconductors, and Solar Cells
Limited-reflective Fiber Units
Application | Ambient temper- ature |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Standard sensing object (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | ||||||
Glass presence detection |
70℃ |
![]() IP40 |
R25 | GIGA: 0 to 15 HS: 0 to 15 ST: 0 to 15 SHS: 0 to 12 |
GIGA: 0 to 15 HS: 0 to 15 ST: 0 to 15 SHS: 0 to 12 |
Soda glass with reflection factor of 7% |
E32-L16-N 2M *1 |
Glass- substrate Alignment |
![]() IP40 |
GIGA: 10 to 20 HS: 10 to 20 ST: 10 to 20 SHS: – |
GIGA: 10 to 20 HS: 10 to 20 ST: 10 to 20 SHS: – |
E32-A08 2M *1 |
|||
300℃ |
![]() IP30 |
E32-A08H2 2M *1 |
|||||
70℃ |
![]() IP40 |
GIGA: 12 to 30 HS: 12 to 30 ST: 12 to 30 SHS: – |
GIGA: 12 to 30 HS: 12 to 30 ST: 12 to 30 SHS: – |
E32-A12 2M | |||
Mapping of glass substrates |
![]() IP40 |
GIGA: 15 to 38 HS: 15 to 38 ST: 15 to 38 SHS: – (Center 25) |
GIGA: 15 to 38 HS: 15 to 38 ST: 15 to 38 SHS: – (Center 25) |
End surface of soda glass with reflection factor of 7% (t = 0.7 mm, rounded edges) |
E32-A09 2M | ||
300°C *2 |
![]() IP40 |
GIGA: 20 to 30 HS: 20 to 30 ST: 20 to 30 SHS: – (Center 25) |
GIGA: 20 to 30 HS: 20 to 30 ST: 20 to 30 SHS: – (Center 25) |
E32-A09H2 2M | |||
Wet processes (Cleaning, Resist developing, and etching) |
60℃ |
![]() IP67 |
R40 | 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm) 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) |
Glass (t=0.7mm) |
E32-L11FP 2M | |
Wet processes (Resist stripping) |
85℃ |
![]() IP67 |
8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm) 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) |
E32-L11FS 2M |
*2 The maximum allowable temperature is not the same for all parts of the Fiber Unit. Refer to the dimensions diagrams
for details.
Must not be repeatedly subject to rapid temperature changes.
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Through-beam Fiber Units
Appli- cation |
Ambient temper- ature |
Aper- ture angle |
Appearance (mm) |
Bending radius of cable |
Sensing distance (mm) | Optical axis diameter (minimum sensing object) |
Models | |
---|---|---|---|---|---|---|---|---|
E3X-HD | E3NX-FA | |||||||
Wafer Mapping |
70°C | 1.5° |
![]() Thickness: 3 mm |
Flexible, R1 |
GIGA: 3,220 HS: 1,200 ST: 1,780 SHS: 500 |
GIGA: 4,000 * HS: 1,800 ST: 2,670 SHS: 500 |
2 dia. (0.1 dia./ 0.03 dia.) |
E32-A03 2M |
![]() Thickness: 3 mm |
R10 | E32-A03-1 2M | ||||||
3.4° |
![]() Thickness: 2 mm |
GIGA: 1,280 HS: 450 ST: 680 SHS: 200 |
GIGA: 1,920 HS: 670 ST: 1,020 SHS: 200 |
1.2 dia. (0.1 dia./ 0.03 dia.) |
E32-A04 2M | |||
4° |
![]() IP50 |
Flexible, R1 |
GIGA: 4,000 * HS: 1,460 ST: 2,200 SHS: 580 |
GIGA: 4,000 * HS: 2,190 ST: 3,300 SHS: 580 |
2 dia. (0.1 dia./ 0.03 dia.) |
E32-T24SR 2M | ||
R10 | GIGA: 4,000 * HS: 1,740 ST: 2,600 SHS: 700 |
GIGA: 4,000 * HS: 2,610 ST: 3,900 SHS: 700 |
E32-T24S 2M |
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
[E3X-HD] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
[E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and
SHS: Super-high-speed mode (30 μs)
2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-HD and the second value is for the E3NX-FA.
3. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
models varies.
Reviews