D4MC-1000
Công tắc hành trình Omron
Economical, High Utility Enclosed Switch
Ratings
Rated voltage | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125 VAC 250 VAC 480 VAC |
10 10 3 |
3 2.5 1.5 |
1.5 1.25 0.75 |
10 10 2.5 |
5 3 1.5 |
2.5 1.5 0.75 |
||
8 VDC 14 VDC 30 VDC 125 VDC 250 VDC |
10 10 6 0.5 0.25 |
3 3 3 0.4 0.2 |
1.5 1.5 1.5 0.4 0.2 |
6 6 5 0.05 0.03 |
5 5 5 0.05 0.03 |
2.5 2.5 2.5 0.05 0.03 |
Inrush current | NC | 30 A max. |
---|---|---|
NO | 15 A max. |
Note:Note:
Note:The above figures are for steady-state currents.
Note:Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
Note:Lamp load has an inrush current of 10 times the steady-state current.
Note:Motor load has an inrush current of 6 times the steady-state current.
Note:The above ratings were tested under the following conditions.
(1) Ambient temperature: +20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency: 20 operations/min
Characteristics
Degree of protection | IP67 | |
---|---|---|
Durability | Mechanical | 10,000,000 operations min. |
Electrical | 500,000 operations min. | |
Operating speed | 0.05 mm/s to 0.5 m/s *1 | |
Operating frequency |
Mechanical | 120 operations/min |
Electrical | 20 operations/min | |
Rated frequency | 50/60 Hz | |
Insulation resistance | 100 M Ω min. (at 500 VDC) | |
Contact resistance | 15 m Ω max. (initial value for the built-in switch when tested alone) | |
Dielectric strength |
Between terminals of the same polarity | 1,000 VAC, 50/60 Hz for 1 min |
Between each terminal and non- current-carrying part |
2,000 VAC, 50/60 Hz for 1 min | |
Rated insulation voltage (Ui) | 1,000 VAC | |
Pollution degree (operating environment) | 3 (IEC947-5-1) | |
Protection against electric shock | Class II | |
PTI (tracking characteristics) | 175 | |
Switch category | D (IEC335) | |
Rated operating current (Ie) | 10 A | |
Rated operating voltage (Ue) | 250 VAC | |
Vibration resistance |
Malfunction | 10 to 55 Hz, 1.5-mm double amplitude *2 |
Shock resistance |
Destruction | 1,000 m/s2 min. |
Malfunction | 100 m/s2 min. *1 *2 | |
Ambient operating temperature | – 10 ° C to +80 ° C (with no icing) | |
Ambient operating humidity | 35% to 95%RH | |
Weight | Approx. 71 g (in case of panel mount plunger) |
Note:Only for models with plungers. (Contact your OMRON representative for information on other models.)
Note:Less than 1 ms under a free state at the operating limits.
List of Models
Actuator | Model | |
---|---|---|
Panel mount plunger |
![]() |
D4MC-5000 |
Panel mount roller plunger |
![]() |
D4MC-5020 |
Panel mount crossroller plunger |
![]() |
D4MC-5040 |
Hinge lever |
![]() |
D4MC-1000 |
Short hinge lever |
![]() |
D4MC-1020 |
Hinge roller lever |
![]() |
D4MC-2000 |
Short hinge roller lever |
![]() |
D4MC-2020 |
One-way action short hinge roller lever |
![]() |
D4MC-3030 |
Note:Note:
1. Use Switches with molded terminals in locations subject to dirt, dust, oil drops, or high humidity. Models are available with lead wires on the right, on the left, and from the bottom.
2. Contact your OMRON representative for information on models certified for international standards.
Reviews