D4E-1C10N

Công tắc hành trình Omron

Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E

Type One-touch connector
type
Screw terminal type
General-
purpose
Micro load General-
purpose
without cable
Micro load
without
cable
General-
purpose
with cable
Micro load
with cable
d4e %5B%5Dn lu 1 9
d4e %5B%5Dn lu 1 10
d4e %5B%5Dn lu 1 11
d4e %5B%5Dn lu 1 12
d4e %5B%5Dn lu 1 13
d4e %5B%5Dn lu 1 14
Actuator Model Model Model Model Model Model
Roller plunger
d4e %5B%5Dn lu 1 1
D4E-1A[]0N D4E-2A10N D4E-1A20N D4E-2A20N D4E-1A21N D4E-2A21N
Crossroller
plunger
d4e %5B%5Dn lu 1 2
D4E-1B[]0N D4E-2B10N D4E-1B20N D4E-2B20N D4E-1B21N D4E-2B21N
Plunger
d4e %5B%5Dn lu 1 3
D4E-1C[]0N D4E-2C[]0N D4E-1C20N D4E-2C20N D4E-1C21N D4E-2C21N
Sealed roller
plunger
d4e %5B%5Dn lu 1 4
D4E-1D[]0N D4E-2D10N D4E-1D20N D4E-2D20N D4E-1D21N D4E-2D21N
Sealed crossroller
plunger
d4e %5B%5Dn lu 1 5
D4E-1E[]0N D4E-1E20N D4E-2E20N D4E-1E21N D4E-2E21N
Sealed plunger
d4e %5B%5Dn lu 1 6
D4E-1F[]0N D4E-2F10N D4E-1F20N D4E-2F20N D4E-1F21N D4E-2F21N
Roller lever
d4e %5B%5Dn lu 1 7
D4E-1G[]0N D4E-2G10N D4E-1G20N D4E-2G20N D4E-1G21N D4E-2G21N
One-way action
roller lever
d4e %5B%5Dn lu 1 8
D4E-1H00N D4E-1H20N D4E-2H20N D4E-1H21N

Note: 1. When ordering, specify the current type by replacing the blank box of the model number with 0 for AC connector
or 1 for DC connector.
2. For the plunger and lever actuator models, the NC and NO terminal indicators are reversed.
3. Models are also available with molded terminals and with molded terminals and operation indicators. Refer to
Catalog.

Plug

For models with connectors, select one of the specified Cables with Connectors (sockets) from the following table.

Applicable limit switches Current Type Type No. of conductors Cable length Model
D4E-[][]00N AC Straight

d4e-[]n_lineup2_1
4 2 m XS2F-A421-D90-F
5 m XS2F-A421-G90-F
D4E-[][]10N DC 2 m XS2F-D421-D80-F
5 m XS2F-D421-G80-F

Ratings

Rated voltage Standard load Micro load
Non-inductive load (A) Inductive load (A) Non-inductive load (A)
Resistive load Lamp load Inductive load Motor load Resistive load
NC NO NC NO NC NO NC NO NC NO
125 VAC
250 VAC
5 (1)
5 (1)
1.5 (1)
1.5 (1)
3 (1)
3 (1)
2 (1)
1
1 (1)
0.5
0.1
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
5 (1)
5 (1)
5 (1)
0.5
0.25




1.5 (1)
1.5 (1)
1.5 (1)
0.05
0.03




0.1
0.1
0.1

Minimum applicable load Standard load Micro load
160 mA at 5 VDC 1 mA at 5 VDC
Inrush current NC 10 A max.
NO 10 A max.

Note: 1. The above current ratings are for a standard current and the values in parentheses are for models with a
connector.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.

Characteristics

Degree of protection IP67
Durability * Mechanical 10,000,000 operations min.
Electrical 500,000 operations min. (5 A at 250 VAC, resistive load)
5,000,000 operations min. (10 mA at 24 VDC, resistive load)
Operating speed 0.1 mm/sec to 0.5 m/sec
Operating frequency Mechanical: 120 operations/min
Electrical: 30 operations/min
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 15 mΩ max. (initial value for the built-in switch when tested alone)
Dielectric strength Between terminals of same
polarity
1,000 VAC, 50/60 Hz for 1 min
Between each terminal and
non-current-carrying metal
part
1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1)
Rated insulation voltage (Ui) 250V
Pollution degree (operating environment) 3 (EN60947-5-1)
Short-circuit protective device (SCPD) 10 A fuse (type gG or gI, IEC60269 approved)
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe) 5 A (EN60947-5-1)
Protection against electric shock Class II (grounding not required with double insulation)
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max.
Ambient operating temperature -10°C to +80°C (with no icing)
Ambient operating humidity 35% to 95%RH
Weight Approx. 86 g (in case of roller plunger)

Note: 1. The above values are initial values.
2. The above ratings may vary depending on the model. Contact your OMRON representative for further details.
* Durability values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to