D4C-3201
Công tắc hành trình Omron
Switches
Standard Switches with No Operation Indicator
Actuator | Ratings | Standard load | Microload | ||||
---|---|---|---|---|---|---|---|
5 A at 250 VAC, 4 A at 30 VDC | 0.1 A at 125 VAC, 0.1 A at 30 VDC | ||||||
Cable | VCTF oil- resistant cable *1 |
VCTF cable *2 |
SJT(O) cable *3 |
VCTF oil- resistant cable *1 |
VCTF cable *2 |
||
Cable length (m) |
Model | ||||||
Pin plunger | ![]() |
3 | D4C-1201 | D4C-1401 | D4C-1601 | D4C-4201 | D4C-4401 |
5 | D4C-1301 | D4C-1501 | D4C-1701 | D4C-4301 | D4C-4501 | ||
Roller plunger | ![]() |
3 | D4C-1202 | D4C-1402 | D4C-1602 | D4C-4202 | D4C-4402 |
5 | D4C-1302 | D4C-1502 | D4C-1702 | D4C-4302 | D4C-4502 | ||
Crossroller plunger |
![]() |
3 | D4C-1203 | D4C-1403 | D4C-1603 | D4C-4203 | D4C-4403 |
5 | D4C-1303 | D4C-1503 | D4C-1703 | D4C-4303 | D4C-4503 | ||
Roller lever | ![]() |
3 | D4C-1220 | D4C-1420 | D4C-1620 | D4C-4220 | D4C-4420 |
5 | D4C-1320 | D4C-1520 | D4C-1720 | D4C-4320 | D4C-4520 | ||
Roller lever, high-sensitivity |
![]() |
3 | D4C-1224 | D4C-1424 | D4C-1624 | D4C-4224 | D4C-4424 |
5 | D4C-1324 | D4C-1524 | D4C-1724 | D4C-4324 | D4C-4524 | ||
Sealed pin plunger |
![]() |
3 | D4C-1231 | D4C-1431 | D4C-1631 | D4C-4231 | D4C-4431 |
5 | D4C-1331 | D4C-1531 | D4C-1731 | D4C-4331 | D4C-4531 | ||
Sealed roller plunger |
![]() |
3 | D4C-1232 | D4C-1432 | D4C-1632 | D4C-4232 | D4C-4432 |
5 | D4C-1332 | D4C-1532 | D4C-1732 | D4C-4332 | D4C-4532 | ||
Sealed crossroller plunger |
![]() |
3 | D4C-1233 | D4C-1433 | D4C-1633 | D4C-4233 | D4C-4433 |
5 | D4C-1333 | D4C-1533 | D4C-1733 | D4C-4333 | D4C-4533 | ||
Plastic rod | ![]() |
3 | D4C-1250 | D4C-1450 | D4C-1650 | D4C-4250 | D4C-4450 |
5 | D4C-1350 | D4C-1550 | D4C-1750 | D4C-4350 | D4C-4550 | ||
Center roller lever |
![]() |
3 | D4C-1260 | D4C-1460 | D4C-1660 | D4C-4260 | D4C-4460 |
5 | D4C-1360 | D4C-1560 | — | D4C-4360 | D4C-4560 |
Plunger Models. Add “-M” to the model number (example: D4C-1202 would be D4C-1202-M). Ask your nearest
OMRON representative for details.
2. Switches with variable roller levers are also available. Ask your nearest OMRON representative for details.
*1. Oil-resistant vinyl cabtire cables; approved by EN and IEC.
*2. Ordinary vinyl cabtire cables.
*3. Switches with SJT(O) Cables (cables approved by UL and CSA) are approved by UL and CSA.
Standard Switches with Operation Indicator (Red)
Actuator | Ratings | 5 A at 125 VAC | 4 A at 30 VDC | |||
---|---|---|---|---|---|---|
Cable | VCTF oil-resistant cable *1 |
VCTF cable *2 |
VCTF oil-resistant cable *1 |
VCTF cable *2 |
||
Cable length (m) | Model | |||||
Pin plunger | ![]() |
3 | D4C-2201 | D4C-2401 | D4C-3201 | D4C-3401 |
5 | D4C-2301 | D4C-2501 | D4C-3301 | D4C-3501 | ||
Roller plunger | ![]() |
3 | D4C-2202 | D4C-2402 | D4C-3202 | D4C-3402 |
5 | D4C-2302 | D4C-2502 | D4C-3302 | D4C-3502 | ||
Crossroller plunger |
![]() |
3 | D4C-2203 | D4C-2403 | D4C-3203 | D4C-3403 |
5 | D4C-2303 | D4C-2503 | D4C-3303 | D4C-3503 | ||
Roller lever | ![]() |
3 | D4C-2220 | D4C-2420 | D4C-3220 | D4C-3420 |
5 | D4C-2320 | D4C-2520 | D4C-3320 | D4C-3520 | ||
Roller lever, high-sensitivity |
![]() |
3 | D4C-2224 | D4C-2424 | D4C-3224 | D4C-3424 |
5 | D4C-2324 | D4C-2524 | D4C-3324 | D4C-3524 | ||
Sealed pin plunger |
![]() |
3 | D4C-2231 | D4C-2431 | D4C-3231 | D4C-3431 |
5 | D4C-2331 | D4C-2531 | D4C-3331 | D4C-3531 | ||
Sealed roller plunger |
![]() |
3 | D4C-2232 | D4C-2432 | D4C-3232 | D4C-3432 |
5 | D4C-2332 | D4C-2532 | D4C-3332 | D4C-3532 | ||
Sealed crossroller plunger |
![]() |
3 | D4C-2233 | D4C-2433 | D4C-3233 | D4C-3433 |
5 | D4C-2333 | D4C-2533 | D4C-3333 | D4C-3533 | ||
Plastic rod | ![]() |
3 | D4C-2250 | D4C-2450 | D4C-3250 | D4C-3450 |
5 | D4C-2350 | D4C-2550 | D4C-3350 | D4C-3550 | ||
Center roller lever |
![]() |
3 | D4C-2260 | D4C-2460 | D4C-3260 | D4C-3460 |
5 | D4C-2360 | D4C-2560 | D4C-3360 | D4C-3560 |
*1. Oil-resistant vinyl cabtire cables; approved by EN and IEC.
*2. Ordinary vinyl cabtire cables.
Standard Switches with Operation Indicator
Actuator | Ratings | 0.1 A at 125 VAC | 0.1 A at 30 VDC | |
---|---|---|---|---|
Cable | VCTF oil-resistant cable * | VCTF oil-resistant cable * | ||
Cable length (m) | Model | |||
Pin plunger | ![]() |
3 | D4C-5201 | D4C-6201 |
5 | — | D4C-6301 | ||
Roller plunger | ![]() |
3 | D4C-5202 | D4C-6202 |
5 | D4C-5302 | D4C-6302 | ||
Crossroller plunger | ![]() |
3 | D4C-5203 | D4C-6203 |
5 | D4C-5303 | D4C-6303 | ||
Roller lever | ![]() |
3 | D4C-5220 | D4C-6220 |
5 | D4C-5320 | D4C-6320 | ||
Roller lever, high-sensitivity | ![]() |
3 | D4C-5224 | D4C-6224 |
5 | D4C-5324 | D4C-6324 | ||
Sealed pin plunger | ![]() |
3 | — | D4C-6231 |
5 | — | D4C-6331 | ||
Sealed roller plunger | ![]() |
3 | D4C-5232 | D4C-6232 |
5 | D4C-5332 | D4C-6332 | ||
Sealed crossroller plunger | ![]() |
3 | — | D4C-6233 |
5 | — | D4C-6333 | ||
Plastic rod | ![]() |
3 | D4C-5250 | D4C-6250 |
5 | D4C-5350 | D4C-6350 |
Note: Ask your nearest OMRON representative for information on Switching with approved international standards.
* Oil-resistant vinyl cabtire cables; approved by EN and IEC.
Pre-wired Models (Use VCTF Oil-resistant Cable)
Actuator | Ratings | 1 A at 125 VAC | 1 A at 30 VDC | ||
---|---|---|---|---|---|
Operation indicator |
Without operation indicator |
With operation indicator |
Without operation indicator |
With operation indicator |
|
Pin plunger | ![]() |
— | — | — | D4C-3001-DK1EJ[] |
Roller plunger | ![]() |
D4C-1002-AK1EJ[] | D4C-2002-AK1EJ[] | D4C-1002-DK1EJ[] | D4C-3002-DK1EJ[] |
Sealed plunger | ![]() |
— | — | — | D4C-3031-DK1EJ[] |
Sealed roller plunger |
![]() |
— | — | D4C-1032-DK1EJ[] | D4C-3032-DK1EJ[] |
Roller lever (high-sensitivity model) |
![]() |
— | D4C-2024-AK1EJ[] | D4C-1024-DK1EJ[] | D4C-3024-DK1EJ[] |
For example: 30 cm → D4C-2002-AK1EJ03
2. M1J models are also available. Contact your OMRON sales representative for further information.
3. Of the above model numbers, some with special specifications are not registered.
Weather-resistant Models
Actuator | Operation indicator | Without operating indication | With operating indication | |||
---|---|---|---|---|---|---|
Ratings | Standard load | Microload | Standard load | |||
5 A at 250 VAC 4 A at 30 VDC |
0.1 A at 125 VAC 0.1 A at 30 VDC |
5 A at 125 VAC | 4 A at 30 VDC | |||
VCTF oil-resistant cable * | ||||||
Cable length (m) | Model | |||||
Roller lever | ![]() |
3 | D4C-1220-P | D4C-4220-P | D4C-2220-P | D4C-3220-P |
5 | D4C-1320-P | — | — | — | ||
Roller lever (high-sensitivity model) |
![]() |
3 | D4C-1224-P | D4C-4224-P | D4C-2224-P | D4C-3224-P |
5 | D4C-1324-P | D4C-4324-P | D4C-2324-P | D4C-3324-P | ||
Adjustable roller lever | ![]() |
3 | D4C-1227-P | D4C-4227-P | D4C-2227-P | D4C-3227-P |
5 | D4C-1327-P | D4C-4327-P | D4C-2327-P | D4C-3327-P | ||
Adjustable rod lever | ![]() |
3 | D4C-1229-P | D4C-4229-P | — | D4C-3229-P |
5 | D4C-1329-P | — | D4C-2329-P | D4C-3329-P |
Note: Silicon rubber is used to increase resistance to the environment. Silicon rubber, however, can generate silicon gas.
(This can occur at room temperature, but the amount of silicon gas generated increases at higher temperatures.)
Silicon gas will react as a result of arc energy and form silicon oxide (SiO2). If silicon oxide accumulates on the
contacts, contact interference can occur and can interfere with the device. Before using a Switch, test it under actual
application conditions (including the environment and operating frequency) to confirm that no problems will occur in
actual.
Applicable Cables
Type | For AC | For DC | ||
---|---|---|---|---|
Appearance | No. of conductors | Cable length | Model | Model |
Straight
![]() |
4 | 2 m | XS2F-A421-D90-F | XS2F-D421-D80-F |
5 m | XS2F-A421-G90-F | XS2F-D421-G80-F |
Mounting Plates (Order Separately)
The WL/WL-N model incorporated by equipment can be replaced with the D4C together with the Mounting Plate without changing the position of the dog or cam.
List of Replaceable Models
WL/WL-N model (Actuator) | D4C model (Actuator) | Plate |
---|---|---|
WLD/WL01D/WLD18-N (Top plunger) |
D4C-[][]01 (Plunger) |
D4C-P001 |
WLD2/WL01D2/WLD28-N (Top roller plunger) |
D4C-[][]02 (Roller plunger) |
D4C-P002 |
WLCA2/WL01CA2/WLCA2-N (Roller lever) |
D4C-[][]20 (Roller lever) |
D4C-P020 |
Note: The WL01[] is for micro loads.
Example of Replacement
Note: The position of the dog remains unchanged.

Individual Parts
Head/Actuator
Actuator | Head (with actuator) | Actuator |
---|---|---|
Pin plunger | D4C-0001 | — |
Roller plunger | D4C-0002 | — |
Crossroller plunger | D4C-0003 | — |
Roller lever | D4C-0020 | WL-1A100 |
Roller lever (weather-resistant model) | — | WL-1A100P1 |
Roller lever (high-sensitivity model) | D4C-0024 | WL-1A100 |
Variable roller lever | D4C-0027 | — |
Variable rod lever | D4C-0029 | HL-1HPA500 |
Sealed pin plunger | D4C-0031 | — |
Sealed roller plunger | D4C-0032 | — |
Sealed crossroller plunger | D4C-0033 | — |
Plastic rod | D4C-0050 | — |
Center roller lever | D4C-0060 | — |
actuator.
2. Actuators for plunger models, plastic rod models, and center roller lever models cannot be ordered individually.
They must be ordered together with the head.