MODEL 2300R đồng hồ kẹp dòng Kyoritsu

Liên hệ

Giao hàng COD toàn quốc

MODEL 2300R Fork Current Tester • True RMS reading is an essential feature for accurate measurement. • “Non Contact” voltage function indicates the presence of AC voltage by warning the user with an audible signal.

Mô Tả Sản Phẩm

MODEL 2300R

Fork Current Tester

• True RMS reading is an essential feature for accurate measurement.
• “Non Contact” voltage function indicates the presence of AC voltage by warning the user with an audible signal.
• Set the DC current range to zero in one touch with the Zero Adjust function.

Thông số kĩ thuật

• True RMS reading is an essential feature for accurate measurement.
• “Non Contact” voltage function indicates the presence of AC voltage by warning the user with an audible signal.
• Set the DC current range to zero in one touch with the Zero Adjust function.

2300R 1

KEW FORK 2300R can be used in crowded connection boxes, where cables are very short, and space is too limited to clamp cables using with a traditional clamp meter.

True RMS (Root Mean Square) Value Measurement

2300R trueRMS

When load current is not affected by the distortion, both averaging value type and true RMS (root mean square) type clamp meters show the almost same value of about 10A with constant wave-form as the above display samples. However, when load current is affected by some distortions such as inverter, etc…,averaging value type clamp meter indicates 5.5A instead of 9.7A and true RMS type clamp meter indicates 7.9A instead of 9.7A with irregular wave-form. Accordingly, true RMS type clamp meter is recommendable for the measurement of the equipment with inverter control devices.
Due to the use of thyristors, inverters and other energy-saving controllers in recent electric wiring, current waveforms often include harmonic components and are distorted compared to sinusoidal waves (50/60Hz).
The Kyoritsu True RMS value tester is able to measure distorted waveforms using true RMS since waveforms are being internally calculated continuously. In contrast, when measurements are made with a averaging value tester, errors are generated in the measurement value because the tester cannot continuously track distorted waveforms.

(Compared to the true RMS value tester, measurement values for the averaging value generate more than 30% errors in some cases.)

Current measurementAC A 0 to 100.0A ±2.0%rdg±5dgt (50/60Hz)
DC A 0 to ±100.0A ±2.0%rdg±5dgt
Crest factor2.5
Non contact voltageDetect AC voltage without contacting with socket wire
During voltage detection, “Hi” flashes and a buzzer sounds
Maximum digit1,049
Conductor sizeMax Ø10mm
Safety StandardIEC 61010-1 CAT III 300V Pollution degree 2
Power sourceR03 (AAA) × 2 (Auto power off: approx.10 minutes)
*Continuous measuring time: AC A approx. 46 hours DC A approx. 52 hours
Dimensions161.3(L) × 40.2(W) × 30.3(D)mm
Weight110g (with batteries)
Included Accessories9113 (Carrying Case)
R03 (AAA) × 2
Instruction Manual

Reviews

There are no reviews yet.

Be the first to review “MODEL 2300R đồng hồ kẹp dòng Kyoritsu”

Your email address will not be published. Required fields are marked *