TL-W5MC1 2M Cảm biến tiệm cận dẹt Omron

331 lượt xem

Ngày: 16/06/2019

Tình trạng : Còn Hàng

Thông tin sản phẩm

645,000

Xin vui lòng liên hệ theo thông tin dưới dây

0936.296.483 (Liên hệ mua hàng) Email: sales@minhquangelectric.com THỜI GIAN LÀM VIỆC: Thứ 2 - thứ 6 / 8:00 AM - 5:00 PM Thứ 7 / 9:00 AM - 11:00 AM (Email only)

0969.100.802 (Dịch vụ kỹ thuật) Email: services@minhquangelectric.com THỜI GIAN LÀM VIỆC: Thứ 2 - thứ 6 / 8:00 AM - 5:00 PM Thứ 7 / 9:00 AM - 11:00 AM (Email only)

TL-W5MC1 2M

Cảm biến tiệm cận dẹt Omron

Standard Flat Sensors in Many Different Variations

• Only 6 mm thick yet provides a sensing distance of 3 mm (TL-W3MC1).

• Aluminum die-cast models also available.

Sensors

DC 2-Wire Models

AppearanceSensing distanceModel
Operation mode
NONC
Unshielded
tl_w_lineup1_1
5 mmTL-W5MD1 2M *1 *2TL-W5MD2 2M *2

DC 3-Wire Models

AppearanceSensing
distance
Output
configuration
Model
Operation mode
NONC
Unshielded
tl_w_lineup1_1
1.5 mmNPNTL-W1R5MC1 2M *1 *2
PNPTL-W1R5MB1 2M
3 mmNPNTL-W3MC1 2M *1 *2TL-W3MC2 2M *1 *2
PNPTL-W3MB1 2M *2TL-W3MB2 2M *2
5 mmNPNTL-W5MC1 2M *1 *2TL-W5MC2 2M
PNPTL-W5MB1 2MTL-W5MB2 2M
20 mmNPNTL-W20ME1 2M *1TL-W20ME2 2M *1
Shielded
tl_w_lineup2_6
5 mmNPNTL-W5E1 2MTL-W5E2 2M
PNPTL-W5F1 2MTL-W5F2 2M

*1. Models with a different frequency are also available to prevent mutual interference.
The model numbers are TL-W[]M[][]5 (e.g., TL-W5MD15).
*2. Models are also available with robotics (bend resistant) cables. Add “-R” to the model number.
(e.g., TL-W5MC1-R 2M)

DC 2-Wire Models

ModelTL-W5MD[]
Sensing distance5 mm ±10%
Set distance0 to 4 mm
Differential travel10% max. of sensing distance
Detectable objectFerrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on
Data Sheet.)
Standard sensing objectIron, 18 × 18 × 1 mm
Response frequency *1500 Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current0.8 mA max.
Control
output
Load current3 to 100 mA
Residual voltage3.3 V max. (under load current of 100 mA with cable length of 2 m)
IndicatorsD1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
Operation mode
(with sensing object
approaching)
D1 Models: NO
D2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.
Protection circuitsLoad short-circuit protection, Surge suppressor
Ambient temperature rangeOperating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity rangeOperating/Storage: 35% to 95% (with no condensation)
Temperature influence±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength1,000 VAC for 1 min between current-carrying parts and case
Vibration resistanceDestruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistanceDestruction: 500 m/s2 3 times each in X, Y, and Z directions
Degree of protectionIEC 60529 IP67, in-house standards: oil-resistant *2
Connection methodPre-wired Models (Standard cable length: 2 m)
Weight (packed state)Approx. 80 g
MaterialsCaseHeat-resistant ABS
Sensing surface
AccessoriesInstruction manual
*1. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object,
and a set distance of half the sensing distance.
*2. For environments that require oil resistance, the upper limit of the ambient operating temperature range is 40°C.

DC 3-Wire Models

ModelTL-W1R5MC1
TL-W1R5MB1
TL-W3MC[]
TL-W3MB[]
TL-W5MC[]
TL-W5MB[]
TL-W5E1
TL-W5E2
TL-W5F1
TL-W5F2
TL-W20ME1
TL-W20ME2
Sensing distance1.5 mm ±10%3 mm ±10%5 mm ±10%20 mm ±10%
Set distance0 to 1.2 mm0 to 2.4 mm0 to 4 mm0 to 16 mm
Differential travel10% max. of sensing distance1% to 15% of sensing distance
Detectable objectFerrous metal
(The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.)
Standard sensing objectIron,
8 × 8 × 1 mm
Iron,
12 × 12 × 1 mm
Iron,
18 × 18 × 1 mm
Iron,
50 × 50 × 1 mm
Response frequency1 kHz min.600 Hz min.500 Hz min.300 Hz min.40 Hz min.
Power supply voltage
(operating voltage
range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.12 to 24 VDC (10 to 30 VDC), ripple (p-p): 20% max.12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Current consumption15 mA max. at 24 VDC (no-load)10 mA max. at
24 VDC (no-load)
15 mA max. at
24 VDC (no-load)
8 mA at 12 VDC,
15 mA at 24 VDC
Control
output
Load
current
TL-W1R5MC1:
NPN open collector
100 mA max. at 30 VDC max.
TL-W1R5MC1/-W3MB[]:
PNP open collector
100 mA max. at 30 VDC max.
TL-W5MC[]:
NPN open collector
50 mA max. at 12 VDC
(30 VDC max.)
100 mA max. at 24 VDC
(30 VDC max.)
TL-W5MB[]:
PNP open collector
50 mA max. at 12 VDC
(30 VDC max.)
100 mA max. at 24 VDC
(30 VDC max.)
200 mA100 mA max. at 12 VDC
200 mA max. at 24 VDC
Residual
voltage
1 V max. (under load current of 100 mA with cable length of 2 m)2 V max. (under load current of 200 mA with cable length of 2 m)1 V max. (under load current of 200 mA with cable length of 2 m)
IndicatorsDetection indicator (red)
Operation mode
(with sensing object
approaching)
NOB1/C1 Models: NO
B2/C2 Models: NC
E1/F1 Models: NO
E2/F2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.
Protection circuitsReverse polarity protection, Surge suppressor
Ambient temperature
range
Operating/Storage: -25 to 70°C (with no icing or condensation) *
Ambient humidity rangeOperating/Storage: 35% to 95% (with no condensation)
Temperature influence±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
Voltage influence±2.5% max. of sensing distance at rated voltage in the rated voltage ±10% range±2.5% max. of sensing distance at rated voltage in the rated voltage ±20% range±2.5% max. of sensing distance at rated voltage in the rated voltage ±10% range
Insulation resistance50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistanceDestruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistanceDestruction: 500 m/s2 3 times each in X, Y, and Z directionsDestruction: 500 m/s2 10 times each in X, Y, and Z directions
Degree of protectionIEC 60529 IP67, in-house standards: oil-resistant *
Connection methodPre-wired Models (Standard cable length: 2 m)
Weight (packed state)Approx. 70 gApprox. 80 gApprox. 100 gApprox. 210 g
MaterialsCaseHeat-resistant ABSAluminum die-castHeat-resistant ABS
Sensing
surface
Heat-resistant ABS
AccessoriesMounting Bracket,
Instruction manual
Instruction manual

* For environments that require oil resistance, the upper limit of the ambient operating temperature range is 40°C.