RD62P2 High-speed counter module 2 kênh iQ-R

56 lượt xem

Ngày: 29/06/2019

Tình trạng : Còn Hàng

Thông tin sản phẩm

Liên hệ

Đảm bảo 100% hàng chính hãng

Dịch vụ khách hàng tốt nhất

0936.296.483 (hotline)

0936.296.483 (Hỗ trợ kỹ thuật)

RD62P2 High-speed counter module 2 kênh iQ-R

High-Speed Counter Modules

The MELSEC iQ-R Series counter modules are capable of 200k pulse/s for the DC input type, and 8M pulse/s for differential input. When used with a high-accuracy incremental encoder, positional tracking can also be realized. It also features a PWM output, which is ideal for applications requiring a measurement of pulse cycles.

 

Pulse measurement

The pulse measurement feature enables measuring of the pulse cycle, which is ideal for various applications such as in the food and beverage industry where proximity sensors are used to control flask position on the conveyor, or the renewable energy industry where the wind vane angle is controlled on a wind turbine.

 

High-speed PWM output

The PWM output frequency can support up to 200 kHz with a minimum 100 ns pulse width (proportion to ‘on’ time) during the required duty cycle. The set values can be changed during operation without having to stop the system, such as in industrial-scale fan control.

 

High-speed counter module specifications

Item RD62P2 RD62P2E RD62D2
Number of channels (ch) 2 2 2
Count input signal
1-phase input (1 multiple/2 multiples)
2-phase input (1 multiple/2 multiples/4 multiples)
CW/CCW input
Signal level (øA, øB) 2…5 mA at 5/12/24 V DC 2…5 mA at 5/12/24 V DC EIA Standard RS-422-A
Differential line driver level
Counter
Counting speed (pulse/s) 10k…200k 10k…200k 10k…8M
Counting range (32-bit signed binary) -2147483648…2147483647 -2147483648…2147483647 -2147483648…2147483647
External input
Preset, function start 7…10 mA at 5/12/24 V DC 7…10 mA at 5/12/24 V DC 7…10 mA at 5/12/24 V DC
Digital filter (ms) 0, 0.1, 1, 10 0, 0.1, 1, 10 0, 0.1, 1, 10
Pulse measurement
Resolution*1 (ns) 100 100 100
Number of points per channel 1 1 1
External output
Coincidence output (2 points/channel) Transistor (sink type) output,
12/24 V DC, 0.5 A/point
Transistor (source type) output,
12/24 V DC, 0.1 A/point
Transistor (sink type) output,
12/24 V DC, 0.5 A/point
PWM output
Output frequency range (kHz) 0200 0200 0200
Duty ratio Multiples of 0.1 µs Multiples of 0.1 µs Multiples of 0.1 µs
Number of output points per channel 2 2 2
Setting change during operation
External interface*2
40-pin connector
*1: Pulse measurement can be performed in the range of 2000 to 2147483647 (0.2 ms to approx. 214 s).
*2: For applicable options, please refer to the relevant product manual.