MR-J4-200B Servo Amplifer Mitsubishi

Liên hệ

Giao hàng COD toàn quốc

Mô Tả Sản Phẩm

MR-J4-200B Servo Amplifer Mitsubishi

Mã hàng MR-J4-200B
Mô tả Servo Amplifier SSCNETIII/H tương thích 2kW 3  pha AC200V~240V
Đơn giá Liên hệ
Tình trạng Đang bán

Servo Amplifier Model Designation

Model Designation for 1-Axis Servo Amplifiericon18

Model Designation for 1-Axis Servo Amplifier

Notes:
  • Dynamic brake which is built in 7 kW or smaller servo amplifiers is removed. When using the servo amplifier without a dynamic brake, the servo motor does not stop immediately at alarm occurrence or power failure. Take measures to ensure safety on the entire system. Refer to relevant Servo Amplifier Instruction Manual for details.
  • A power supply of 1-phase 200 V AC is supported by 0.1 kW to 2 kW servo amplifiers.
  • A power supply of 3-phase 400 V AC is supported by 0.6 kW and 0.1 kW or larger servo amplifiers.
  • Available in 11 kW to 22 kW servo amplifiers. A regenerative resistor (standard accessory) is not enclosed. Refer to relevant Servo Amplifier Instruction Manual for details.
  • A power supply of 1-phase 100 V AC is supported by 0.1 kW to 0.4 kW servo amplifiers.
  • MR-J4-_B_-LL is available. Refer to “MR-J4-_B_-LL MR-J4-DU_B_-LL Servo Amplifier Instruction Manual” for the pressure control compatible servo amplifiers.
  • The special coating (JIS C60721-3-3/IEC 60721-3-3 classification 3C2) is applied to the circuit board of the servo amplifier. Refer to relevant Servo Amplifier Instruction Manual for details.
  • The positioning mode is supported by MR-J4-GF(-RJ)/MR-J4-A-RJ servo amplifiers.
  • Supported by MR-J4-03A6(-RJ) servo amplifier.
  • Only the positioning mode is supported by MR-J4-03A6-RJ. The fully closed loop control, load-side encoder A/B/Z-phase input, and the functional safety unit are not supported.
  • Only 200 V is available.
  • For the servo amplifier software version which supports each function, refer to the specification page of each unit.
  • When the servo amplifier is connected to CC-Link IE Field Network Basic, an MR-D30 functional safety unit is not supported.
  • Available with MR-J4-B/MR-J4-A.

Model Designation for Multi-Axis Servo Amplifiericon19

Model Designation for Multi-Axis Servo Amplifier

Notes:
  • Dynamic brake which is built in servo amplifiers is removed. When using the servo amplifier without a dynamic brake, the servo motor does not stop immediately at alarm occurrence or power failure. Take measures to ensure safety on the entire system. Refer to relevant Servo Amplifier Instruction Manual for details.
  • A-axis, B-axis, and C-axis indicate names of axes of the multi-axis servo amplifier. The C-axis is available for the 3-axis servo amplifier.
  • Supported by MR-J4W2-0303B6 servo amplifier.
  • The special coating (JIS C60721-3-3/IEC 60721-3-3 classification 3C2) is applied to the circuit board of the servo amplifier. Refer to relevant Servo Amplifier Instruction Manual for details.
  • A power supply of 1-phase 200 V AC is supported by 0.2 kW to 0.75 kW servo amplifiers.
  • For the servo amplifier/drive unit software version which supports each function, refer to the specification page of each unit.
  • Available only with 0.2 kW and 0.4 kW.

Unit Model Designation

Model Designation for Drive Uniticon20

Model Designation for Drive Unit

Notes:
  • The special coating (JIS C60721-3-3/IEC 60721-3-3 classification 3C2) is applied to the circuit board of the servo amplifier and the drive unit of 30 kW or larger. Refer to relevant Servo Amplifier Instruction Manual for details.
  • A power supply of 3-phase 200 V AC is supported by 37 kW or smaller drive units.
  • Available only with MR-J4-DU_B_(-RJ).
  • Positioning mode is supported by MR-J4-DU_A_-RJ drive unit.
  • MR-J4-DU_B_-LL is available in 30 kW or larger drive units. Refer to “MR-J4-_B_-LL MR-J4-DU_B_-LL Servo Amplifier Instruction Manual” for the pressure control compatible servo amplifiers.
  • For the servo amplifier/drive unit software version which supports each function, refer to the specification page of each unit.
  • Supported by 3-phase 400 V AC, 45 kW or larger drive units.

Model Designation for Power Regeneration Converter Unit (Note 1)icon21

Model Designation for Power Regeneration Converter Unit (Note 1)

Notes:
  • The power regeneration converter unit is supported only by MR-J4-DU_B(4)(-RJ) drive unit. It is not supported by MR-J4-DU_A(4)(-RJ) drive unit. Refer to “MR-CV_ MR-CR55K_ MR-J4-DU_B_(-RJ) MR-J4-DU_A_(-RJ) Instruction Manual” for the combination with MR-J4-_B(4)(-RJ) servo amplifiers.
  • Available only with the power regeneration converter unit of 400 V.

Model Designation for Resistance Regeneration Converter Unit (Note 1)icon20

Model Designation for Resistance Regeneration Converter Unit (Note 1)

Notes:
  • One unit of resistance regeneration converter unit is required for each drive unit.
  • The special coating (JIS C60721-3-3/IEC 60721-3-3 classification 3C2) is applied to the circuit board of the resistance regeneration converter unit. Refer to “MR-CV_ MR-CR55K_ MR-J4-DU_B_(-RJ) MR-J4-DU_A_(-RJ) Instruction Manual” for details.

Reviews

There are no reviews yet.

Be the first to review “MR-J4-200B Servo Amplifer Mitsubishi”

Your email address will not be published. Required fields are marked *