G9SA-321-T30

Rơ le an toàn

The G9SA Series Offers a Complete Line-up of Compact Units

• Four kinds of 45-mm wide Units are available:

AC/DC24

A 3-pole model, a 5-pole model, and models with 3 poles and 2 OFF-delay poles, as well as a Two-hand Controller.
Also available are 17.5-mm wide Expansion Units with 3 poles and 3 OFF-delay poles.

• Simple expansion connection.

• OFF-delay models have 15-step OFF-delay settings.

• Conforms to EN ISO13849-1 (PLe/Safety Category 4).

• Both DIN track mounting and screw mounting are possible.

G9SA Master Units

Emergency-stop Units

Main contactsAuxiliary contactNumber of input channelsRated voltageModel
3PST-NOSPST-NC1 channel or 2 channels possible24 VAC/VDCG9SA-301
100 to 240 VAC
5PST-NO24 VAC/VDCG9SA-501
100 to 240 VAC

Emergency-stop OFF-delay Units

Main
contacts
OFF-delay
contacts
Auxiliary
contact
Number of
input channels
OFF-delay
time
Rated voltageModel
3PST-NODPST-NOSPST-NC1 channel or 2 channels
possible
7.5 s24 VAC/VDCG9SA-321-T075
100 to 240 VAC
15 s24 VAC/VDCG9SA-321-T15
100 to 240 VAC
30 s24 VAC/VDCG9SA-321-T30
100 to 240 VAC
Note: Set to maximum values in the factory.
* The following 15-step OFF-delay time settings are available:
T075: 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6, 6.5, 7, and 7.5 s
T15: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, and 15 s
T30: 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, and 30 s

Two-hand Controller

Main contactsAuxiliary contactNumber of input channelsRated voltageModel
3PST-NOSPST-NC2 channels24 VAC/VDCG9SA-TH301
100 to 240 VAC

Expansion Unit

Expansion Unit

The Expansion Unit connects to a G9SA-301, G9SA-501, G9SA-321, or G9SA-TH301.

Main contactsAuxiliary contactModel
3PST-NOSPST-NCG9SA-EX301

Expansion Units with OFF-delay Outputs

The Expansion Unit connects to a G9SA-301, G9SA-501 or G9SA-321.

Main contact formAuxiliary contactOFF-delay timeModel
3PST-NOSPST-NC7.5 sG9SA-EX031-T075
15 sG9SA-EX031-T15
30 sG9SA-EX031-T30
Note: Set to maximum values in the factory.
* The following 15-step OFF-delay time settings are available:
T075: 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6, 6.5, 7, and 7.5 s
T15: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, and 15 s
T30: 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, and 30 s