G3PE-225B DC12-24

Rơ le bán dẫn tích hợp tản nhiệt Omron

Compact, Slim-profile SSRs with Heat Sinks. Models with No Zero Cross for a Wide Range of Applications

• RoHS compliant.

• Models also available with no zero cross

• Surge pass protection improved surge dielectric strength for output currents. (OMRON testing)

• Compact with a slim profile.

• Mount to DIN Track or with screws.

• Conforms to UL, CSA, and EN standards (TÜV certification).

Certification

UL508, CSA22.2 No.14, and EN60947-4-3

Ratings

Input (at an Ambient Temperature of 25°C)

ModelRated voltageOperating
voltage range
Rated input
current
Voltage level
Must operate voltageMust release voltage
G3PE-[][][]B12 to 24 VDC9.6 to 30 VDC7 mA max.9.6 VDC max.1.0 VDC max.
G3PE-[][][]BL15 mA max.

Output

ModelG3PE-
215B(L)
G3PE-
225B(L)
G3PE-
235B(L)
G3PE-
245B(L)
G3PE-
515B(L)
G3PE-
525B(L)
G3PE-
535B(L)
G3PE-
545B(L)
Rated load
voltage
100 to 240 VAC (50/60 Hz)200 to 480 VAC (50/60 Hz)
Load voltage
range
75 to 264 VAC (50/60 Hz)180 to 528 VAC (50/60 Hz)
Applicable
load current *
0.1 to 15 A
(at 40 °C)
0.1 to 25 A
(at 40 °C)
0.5 to 35 A
(at 25 °C)
0.5 to 45 A
(at 25 °C)
0.1 to 15 A
(at 40 °C)
0.1 to 25 A
(at 40 °C)
0.5 to 35 A
(at 25 °C)
0.5 to 45 A
(at 25 °C)
Inrush current
resistance
150 A
(60 Hz,
1 cycle)
220 A
(60 Hz,
1 cycle)
440 A
(60 Hz, 1 cycle)
150 A
(60 Hz,
1 cycle)
220 A
(60 Hz,
1 cycle)
440 A
(60 Hz, 1 cycle)
Permissible I2t
(reference value)
121A2s260A2s1,260A2s128A2s1,350A2s6,600A2s
Applicable load
(resistive load)
3 kW
(at 200
VAC)
5 kW
(at 200
VAC)
7 kW
(at 200
VAC)
9 kW
(at 200
VAC)
6 kW
(at 400
VAC)
10 kW
(at 400
VAC)
14 kW
(at 400
VAC)
18 kW
(at 400
VAC)
* The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient
Temperature in Engineering Data on Data Sheet.

Characteristics

ModelG3PE
-215B
G3PE
-225B
G3PE
-235B
G3PE
-245B
G3PE
-215BL
G3PE
-225BL
G3PE
-235BL
G3PE
-245BL
Operate time1/2 of load power source cycle + 1 ms max.1 ms max.
Release time1/2 of load power source cycle + 1 ms max.
Output ON voltage drop1.6 V (RMS) max.
Leakage current10 mA max. (at 200 VAC)
Insulation resistance100 MΩ min. (at 500 VDC)
Dielectric strength2,500 VAC, 50/60 Hz for 1 min
Vibration resistance10 to 55 to10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
(Mounted to DIN track)
Shock resistanceDestruction: 294 m/s2 (Mounted to DIN track)
Ambient storage
temperature
– 30 to 100 °C (with no icing or condensation)
Ambient operating
temperature
– 30 to 80 °C (with no icing or condensation)
Ambient operating
humidity
45% to 85%
WeightApprox. 240 gApprox. 400 gApprox. 240 gApprox. 400 g
ModelG3PE
-515B
G3PE
-525B
G3PE
-535B
G3PE
-545B
G3PE
-515BL
G3PE
-525BL
G3PE
-535BL
G3PE
-545BL
Operate time1/2 of load power source cycle + 1 ms max.1 ms max.
Release time1/2 of load power source cycle + 1 ms max.
Output ON voltage drop1.8 V (RMS) max.
Leakage current20 mA max. (at 480 VAC)
Insulation resistance100 MΩ min. (at 500 VDC)
Dielectric strength2,500 VAC, 50/60 Hz for 1 min
Vibration resistance10 to 55 to10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
(Mounted to DIN track)
Shock resistanceDestruction: 294 m/s2 (Mounted to DIN track)
Ambient storage
temperature
– 30 to 100 °C (with no icing or condensation)
Ambient operating
temperature
– 30 to 80 °C (with no icing or condensation)
Ambient operating
humidity
45% to 85%
WeightApprox. 240 gApprox. 400 gApprox. 240 gApprox. 400 g