FX5-CCL-MS

Mô đun CC-link Master

CC-Link IE field network

ModelMaster station functionRemote,
slave function
DistanceCompatible CPU module
FX5UFX5UC
FX5-CCLIEF
CC-Link IE field network
(Intelligent device station)
×100 m*1

Up to 1 module
*1 *2

Up to 1 module

*1: Supported in version 1.030 or later.
*2: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

CC-Link

ModelMaster station functionRemote,
slave function
DistanceCompatible CPU module
FX5UFX5UC
FX5-CCL-MS
CC-Link system
master/intelligent
device module
1200 m*1
FX3U-16CCL-M *2
CC-Link
(Master station)
×1200 m*3

Up to
1 module
*3

Up to
1 module
FX3U-64CCL
CC-Link
(Intelligent device station)
×

*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.

*2: When CC-Link master and AnyWire Bitty master or AnyWireASLINK master are used together, connect to the front stage (left side) of AnyWire Bitty master and AnyWireASLINK master. When used together, please refer to the FX3U-128ASL-M, FX3U-128BTY-M, and FX3U-16CCL-M user’s manuals.

*3: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.

Ethernet

ModelData
transmission speed
Maximum
segment length
Supported protocolNo. of connections
FX5U CPU module100 / 10 Mbps100 m
(The distance between hub and node)
・MELSOFT connection
・SLMP (3E frame)
・Socket communication
・Predefined protocol support
Total of 8 connections for MELSOFT connection, SLMP, socket communication, and Predefined protocol support
(Up to 8 external devices are accessible to one CPU module at a time.)
FX5UC CPU module

Sensor Solution

ModelTransmission protocolNumber of connected I/O pointsCompatible CPU module
FX5UFX5UC
FX5-ASL-M
AnyWireASLINK system master module
Dedicated protocol
(AnyWireASLINK)
384 points maximum *1
(input: maximum 256 points,
output: maximum 256 points)
*2
FX3U-128BTY-M *3
AnyWire Bitty series
master
Dedicated protocol
(AnyWire Bitty)
Up to 128 points*4

Up to
1 module
*4

Up to
1 module
FX3U-128ASL-M *3
AnyWireASLINK system master
Dedicated protocol
(AnyWireASLINK)

*1: The number of available remote I/O points per system varies depending on the number of I/O points of the extension devices.
*2: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.

*3: When CC-Link master and AnyWire Bitty master or AnyWireASLINK master are used together, connect to the front stage (left side) of AnyWire Bitty master and AnyWireASLINK master. When used together, please refer to the FX3U-128ASL-M, FX3U-128BTY-M, and FX3U-16CCL-M user’s manuals.

*4: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.

MODBUS communication

ModelCommunication interfaceMaximum transmission distanceGeneric SpecificationsCompatible CPU module
FX5UFX5UC
FX5-232-BDRS-232C15 m・Predefined protocol: RTU
・No. of connectable slaves: 1

Up to
1 modules
×
FX5-232ADP
Up to
2 modules

Up to
2 modules
FX5U CPU moduleRS-48550 m・Predefined protocol: RTU
・No. of connectable slaves: 32
FX5UC CPU module
FX5-485-BD50 m
Up to
1 module
×
FX5-485ADP1200 m
Up to
2 module

Up to
2 module

Serial communication

ModelCommunication interfaceMaximum transmission distanceFunction typeCompatible CPU module
FX5UFX5UC
FX5-232-BDRS-232C15 m・MELSEC Communication protocol (3C/4C frames)
・Non-protocol communication
・Predefined protocol support

Up to
1 module
×
FX5-232ADP
Up to
2 module

Up to
2 module
FX5U CPU moduleRS-48550 m・N:N network
・MELSEC Communication protocol (3C/4C frames)
・Inverter communication
・Non-protocol communication
・Predefined protocol support
FX5UC CPU module
FX5-485-BD50 m
Up to
1 module
×
FX5-485ADP1200 m
Up to
2 module

Up to
2 module
FX5-422-BD-GOTRS-422As per GOT specifications・GOT connection
Up to
1 module