FX5-CNV-BUS mô đun chuyển đổi bus

1.002 lượt xem

Ngày: 18/06/2019

Tình trạng : Còn Hàng

Thông tin sản phẩm

548,000

Xin vui lòng liên hệ theo thông tin dưới dây

0816914999 (Liên hệ mua hàng) Email: sales@minhquangelectric.com THỜI GIAN LÀM VIỆC: Thứ 2 - thứ 6 / 8:00 AM - 5:00 PM Thứ 7 / 9:00 AM - 11:00 AM (Email only)

0969.100.802 (Dịch vụ kỹ thuật) Email: services@minhquangelectric.com THỜI GIAN LÀM VIỆC: Thứ 2 - thứ 6 / 8:00 AM - 5:00 PM Thứ 7 / 9:00 AM - 11:00 AM (Email only)

FX5-CNV-BUS

Mô đun chuyển đổi bus

Extension power supply module

ModelSpecificationsCompatible CPU module
FX5UFX5UC
FX5-1PSU-5VPower supply for FX5 extension module
Internal 5V DC: 1.2 A *1
Internal 24 V DC: 0.3 A *1

Up to
2 modules
*3
×
FX3U-1PSU-5VPower supply for FX3 extension module
Internal 5 V DC: 1 A *1
Internal 24 V DC: 0.3 A *1
*2

Up to
2 modules
*3
×
FX5-C1PS-5VPower supply for FX5 extension module
[Output current]
5 V DC: 1200 mA *1
24 V DC: 625 mA *1
*4

Up to
2 modules

*1: Maximum output current depends on the ambient temperature.
*2: When connecting to FX5U, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.
*3: Max. of total two FX5-1PSU-5V and FX3U-1PSU-5V can be connected in one system.
*4: When connecting to FX5U, FX5-CNV-IF is required.

Connector conversion module

ModelSpecificationsCompatible CPU module
FX5UFX5UC
FX5-CNV-IFConnector conversion module used from FX5 (extension cable type)
to connect FX5 (extension connector type) extension modules.
Control power: not consumed

Up to
1 module
×
FX5-CNV-IFCConnector conversion module used from FX5 (extension connector type)
to connect FX5 (extension cable type) extension modules.
Control power: not consumed
×
Up to
1 module

Connector conversion adapter

ModelSpecificationsCompatible CPU module
FX5UFX5UC
FX5-CNV-BCConnector conversion adapter
Up to
1 module

Up to
1 module

Extension cable

ModelLengthApplicationCompatible CPU module
FX5UFX5UC
FX5-30EC0.3mExtension cable for extension module
Up to
1 module

Up to
1 module
FX5-65EC0.65m

Bus conversion module

ModelSpecificationsCompatible CPU module
FX5UFX5UC
FX5-CNV-BUSBus conversion FX5 (extension cable type) -> FX3 extension
Control power: 5 V DC 150 mA (supplied from PLC)

Up to
1 module
*1

Up to
1 module
FX5-CNV-BUSCBus conversion FX5 (extension connector type) -> FX3 extension
Control power: 5 V DC 150 mA (supplied from PLC)
*2

Up to
1 module

Up to
1 module

*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to FX5UC.
*2: FX5-CNV-IF is necessary to connect to FX5U.

Terminal modules

Terminal modules are used to convert connector-type I/O terminals into terminal blocks.
By using terminal blocks (built-in element type) dedicated to input or output, capturing of AC input signals and format conversion into the relay/transistor/triac output can be performed.

ModelNo. of input
points
No. of output
points
Function
FX-16E-TB16 input points or 16 output pointsDirectly connected to the I/O terminal of PLC.
Using this unit instead of a terminal block or relaying a wiring of I/O device located remotely from PLC enables reducing of the man-hours of I/O wiring.
FX-16E-TB/UL
FX-32E-TB32 input points, 32 output points, or
16 input points and 16 output points
FX-32E-TB/UL
FX-16EX-A1-TB16 points100 V AC input type
FX-16EYR-TB16 pointsRelay output type
FX-16EYR-ES-TB/UL
FX-16EYS-TBTriac output type
FX-16EYS-ES-TB/UL
FX-16EYT-TBTransistor output type (sink)
FX-16EYT-ES-TB/UL
FX-16EYT-ESS-TB/ULTransistor output type (source)

SD memory card

ModelSpecificationsCompatible CPU module
TypeCapacityNumber of writesFX5UFX5UC
NZ1MEM-2GBSDSD memory card2G bytes60,000 times
Up to
1 module

Up to
1 module
NZ1MEM-4GBSDSDHC memory card4G bytes100,000 times
NZ1MEM-8GBSD8G bytes
NZ1MEM-16GBSD16G bytes

Battery

ModelApplicationCompatible CPU module
FX5UFX5UC
FX3U-32BLThe battery will be used when you desire to retain (latch) * the status of the device memory or clock data before a power failure.
At the time of delivery from a plant, the battery is not built in the CPU module.
Please make arrangements if required.

Up to
1 module

Up to
1 module

*: Setting of parameter is required for a power failure retention.

Cable

ModelLengthApplication
FX-232CAB-13.0 mUse a communication cable to connect a PLC with a personal computer by RS-232C communication.
FX5-232ADP <-> Personal computer
FX5-232-BD * <-> Personal computer

*: FX5-232-BD can be connected to the FX5U CPU module.