E5AC-TQX4ASM-008

Điều khiển nhiệt độ theo bước Omron

96 × 96 mm. Programmable Controllers Join the E5[]C Series! Program up to 256 segments can handle a wide variety of applications

Ratings

Power supply voltageA in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range85 to 110% of rated supply voltage
Power consumption9.0 VA max. at 100 to 240 VAC, and 5.6 VA max. at 24 VAC or 3.4 W max. at 24 VDC
Sensor inputTemperature input
Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to
260°C
Analog input
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedanceCurrent input: 150 Ω max., Voltage input: 1 MΩ min.
(Use a 1:1 connection when connecting the ES2-HB-N/THB-N.)
Control method2-PID control (with auto-tuning) or ON/OFF control
Control
output
Relay outputSPST-NO, 250 VAC, 5 A (resistive load), electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA (reference value)
Voltage output
(for driving SSR)
Output voltage: 12 VDC ± 20% (PNP), max. load current: 40 mA, with short-circuit
protection circuit (The maximum load current is 21 mA for models with two control
outputs.)
Linear current
output
4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
Auxiliary
output
Number of outputs4
Output
specifications
SPST-NO. relay outputs, 250 VAC, Models with 4 outputs: 2 A (resistive load),
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference
value)
Event
input
Number of inputs2, 4 or 6 (depends on model)
External contact
input
specifications
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Transfer
output
Number of outputs1 (only on models with a transfer output)
Output
specifications
Current output: 4 to 20 mA DC, Load: 500 Ω max., Resolution: Approx. 10,000
Linear voltage output: 1 to 5 VDC, load: 1 kΩ min., Resolution: Approx. 10,000
Potentiometer input100 Ω to 10 kΩ
Setting methodDigital setting using front panel keys
Indication method11-segment digital display and individual indicators
Character height: PV: 25.0 mm, SV: 15.0 mm, MV: 9.5 mm
Three displays. Contents: PV, SP, program No. and segment No., remaining segment
time, or MV (valve opening)
Numbers of digits: 4 digits
Bank switchingNone
Other functionsManual output, heating/cooling control, loop burnout alarm, other alarm functions,
heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV
limiter, input digital filter, robust tuning, PV input shift, protection functions, extraction of
square root, MV change rate limit, logic operations, temperature status display, moving
average of input value, and display brightness setting
Ambient operating
temperature
-10 to 55°C (with no condensation or icing), For 3-year warranty: -10 to 50°C with
standard mounting (with no condensation or icing)
Ambient operating humidity25 to 85%
Storage temperature-25 to 65°C (with no condensation or icing)
Altitude2,000 m max.
Recommended fuseT2A, 250 VAC, time-lag, low-breaking capacity
Installation environmentOvervoltage category II, Pollution Degree 2 (EN/IEC/UL 61010-1)

Input Ranges

Thermocouple/Platinum Resistance Thermometer (Universal inputs)

Analog input

Input typeCurrentVoltage
Input specification4 to 20 mA0 to 20 mA1 to 5 V0 to 5 V0 to 10 V
Setting rangeUsable in the following ranges by scaling:
-1999 to 9999, -199.9 to 999.9,
-19.99 to 99.99 or -1.999 to 9.999
Set value2526272829

Alarm Types

Each alarm can be independently set to one of the following 17 alarm types. The default is 2: Upper limit. (see note.)
Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
Note: In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1
parameter is not displayed.
To use alarm 1, set the output assignment to alarm 1.

Characteristics

Indication accuracy
(at the ambient
temperature of 23°C)
Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1
Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater)
±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Potentiometer input: ±5% FS ±1 digit max.
Transfer output accuracy±0.3% FS max.
Influence of
temperature *2
Thermocouple input (R, S, B, C/W, PL II): (±1% of indication value or ±10°C, whichever is
greater) ±1 digit max.
Other thermocouple input: (±1% of indication value or ±4°C, whichever is greater) ±1 digit
max. *3
Platinum resistance thermometer: (±1% of indication value or ±2°C, whichever is greater) ±1
digit max.
Analog input: ±1%FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Influence of voltage *2
Influence of EMS.
(at EN 61326-1)
Input sampling period50ms
HysteresisTemperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or°F)
Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)
Proportional band (P)Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)
Analog input: 0.1 to 999.9% FS (in units of 0.1% FS)
Integral time (I)Standard, heating/cooling, or Position-proportional (Close): 0 to 9999 s (in units of 1 s), 0.0
to 999.9 s (in units of 0.1 s)
Position-proportional (Floating): 1 to 9999 s (in units of 1 s), 0.1 to 999.9 s (in units of 0.1 s)
*4
Derivative time (D)0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4
Proportional band (P)
for cooling
Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)
Analog input: 0.1 to 999.9% FS (in units of 0.1% FS)
Integral time (I) for
cooling
0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4
Derivative time (D) for
cooling
0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *4
Control period0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)
Manual reset value0.0 to 100.0% (in units of 0.1%)
Alarm setting range-1999 to 9999 (decimal point position depends on input type)
Influence of signal
source resistance
Thermocouple: 0.1°C/Ω max. (100 Ω max.)
Platinum resistance thermometer: 0.1°C/Ω max. (10 Ω max.)
Insulation resistance20 MΩ min. (at 500 VDC)
Dielectric strength3,000 VAC, 50/60 Hz for 1 min between terminals of different charge
VibrationMalfunction10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
Resistance10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions
ShockMalfunction100 m/s2, 3 times each in X, Y, and Z directions
Resistance300 m/s2, 3 times each in X, Y, and Z directions
WeightController: Approx. 250 g, Mounting Adapter: Approx. 4 g × 2
Degree of protectionFront panel: IP66, Rear case: IP20, Terminals: IP00
Memory protectionNon-volatile memory (number of writes: 1,000,000 times)
Setup ToolCX-Thermo version 4.61 or higher
Setup Tool portE5AC-T top panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect to a USB
port on the computer.*5
E5AC-T front panel: An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E
Conversion Cable are used together to connect to a USB port on the computer.*5
StandardsApproved
standards
cULus: UL 61010-1/CSA C22.2 No.61010-1, Korean wireless regulations (Radio law: KC
Mark) (Some models only.) *6
Conformed
standards
EN 61010-1 (IEC 61010-1), RCM
EMCEMI EN 61326-1 *7
Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A
Noise Terminal Voltage: EN 55011 Group 1, class A
EMS: EN 61326-1 *7
ESD Immunity: EN 61000-4-2
Electromagnetic Field Immunity: EN 61000-4-3
Burst Noise Immunity: EN 61000-4-4
Conducted Disturbance Immunity: EN 61000-4-6
Surge Immunity: EN 61000-4-5
Voltage Dip/Interrupting Immunity: EN 61000-4-11
*1. The indication accuracy of K thermocouples in the -200 to 1300°C range, T and N thermocouples at a temperature of
-100°C max., and U and L thermocouples at any temperatures is ±2°C ±1 digit max. The indication accuracy of the
B thermocouple at a temperature of 400°C max. is not specified. The indication accuracy of B thermocouples at a
temperature of 400 to 800°C is ±3°C max. The indication accuracy of the R and S thermocouples at a temperature
of 200°C max. is ±3°C ±1 digit max. The indication accuracy of C/W thermocouples is (±0.3% of PV or ±3°C,
whichever is greater) ±1 digit max. The indication accuracy of PL II thermocouples is (±0.3% of PV or ±2°C,
whichever is greater) ±1 digit max.
*2. Ambient temperature: -10°C to 23°C to 55°C, Voltage range: -15% to 10% of rated voltage
*3. K thermocouple at -100°C max.: ±10°C max.
*4. The unit is determined by the setting of the Integral/Derivative Time Unit parameter.
*5. External communications (RS-485) and USB-serial conversion cable communications can be used at the same time.
*6. Refer to your OMRON website for the most recent information on applicable models.
*7. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)

Program Control

Number of programs (patterns)8
Number of segments (steps)32
Segment setting methodTime setting (Segment set with set point and time.)
Slope setting (Segment set with segment type, set point, slope, and time.)
Segment times0 h 0 min to 99 h 59 min
0 min 0 s to 99 min 59 s
Alarm settingSet separately for each program.
Reset operationSelect either stopping control or fixed SP operation.
Startup operationSelect continuing, resetting, manual operation, or run mode.
PID setsNumber of sets8
Setting methodSet separately for each program (automatic PID group selection also supported).
Alarm SP functionSelect from ramp SP and target SP.
Program
status control
Segment operationAdvance, segment jump, hold, and wait
Program operationProgram repetitions and program links
Wait operationWait methodWaiting at segment ends
Wait width settingSame wait width setting for all programs
Time signalsNumber of outputs2
Number of ON/OFF
Operations
1 each per output
Setting methodSet separately for each program.
Program status outputProgram end output (pulse width can be set), run output, stage output
Program
startup
operation
PV startSelect from segment 1 set point, slope-priority PV start
Standby0 h 0 min to 99 h 59 min
0 day 0 h to 99 day 23h
Operation end operationSelect from resetting, continuing control at final set point, and fixed SP control.
Program SP shiftSame program SP shift for all programs

USB-Serial Conversion Cable

Applicable OSWindows XP/Vista/7/8/10 *1
Applicable softwareCX-Thermo version 4.61 or higher
Applicable modelsE5[]C-T Series, E5[]C Series, and E5CB Series
USB interface standardConforms to USB Specification 2.0.
DTE speed38,400 bps
Connector specificationsComputer: USB (type A plug)
Digital Temperature Controller: Special serial connector
Power supplyBus power (Supplied from USB host controller.) *2
Power supply voltage5 VDC
Current consumption450 mA max.
Output voltage4.7 ± 0.2 VDC (Supplied from USB-Serial Conversion Cable to the Digital
Temperature Controller.)
Output current250 mA max. (Supplied from USB-Serial Conversion Cable to the Digital
Temperature Controller.)
Ambient operating temperature0 to 55°C (with no condensation or icing)
Ambient operating humidity10% to 80%
Storage temperature-20 to 60°C (with no condensation or icing)
Storage humidity10% to 80%
Altitude2,000 m max.
WeightApprox. 120 g
Windows is a registered trademark of Microsoft Corporation in the United States and or other countries.
*1. CX-Thermo version 4.65 or higher runs on Windows 10.
*2. Use a high-power port for the USB port.
Note: A driver must be installed on the computer. Refer to the Instruction Manual included with the Cable for the
installation procedure.

Communications Specifications

Transmission line connection methodRS-485: Multidrop
CommunicationsRS-485 (two-wire, half duplex)
Synchronization methodStart-stop synchronization
ProtocolCompoWay/F, or Modbus
Baud rate *9600, 19200, 38400, or 57600 bps
Transmission codeASCII
Data bit length *7 or 8 bits
Stop bit length *1 or 2 bits
Error detectionVertical parity (none, even, odd)
Block check character (BCC) with CompoWay/F or CRC-16 Modbus
Flow controlNone
InterfaceRS-485
Retry functionNone
Communications buffer217 bytes
Communications response wait time0 to 99 ms
Default: 20 ms
* The baud rate, data bit length, stop bit length, and vertical parity can be individually set using the Communications
Setting Level.

Communications Functions

Programless
communications
*
You can use the memory in the PLC to read and write E5[]C-T parameters, start and reset operation,
etc. The E5[]C-T automatically performs communications with PLCs. No communications
programming is required.
Number of connected Digital Temperature Controllers: 32 max.
Applicable PLCs
OMRON PLCs CS Series, CJ Series, CP Series, NJ Series, or NX1P
Mitsubishi Electric PLCs MELSEC Q Series, L Series, or iQ-R Series
Component
Communications
When Digital Temperature Controllers are connected, set points and RUN/STOP commands can be
sent from the Digital Temperature Controller that is set as the master to the Digital Temperature
Controllers that are set as slaves.
Slope and offsets can be set for the set point.
Number of connected Digital Temperature Controllers: 32 max. (including master)
Copying *When Digital Temperature Controllers are connected, the parameters can be copied from the Digital
Temperature Controller that is set as the master to the Digital Temperature Controllers that are set
as slaves.

MELSEC is a registered trademark of Mitsubishi Electric Corporation.
* Both the programless communications and the component communications support the copying.

Current Transformer (Order Separately) Ratings

E54-CT1
E54-CT3
E54-CT1L
E54-CT3L
Dielectric strength1,000 VAC for 1 min1,500 VAC for 1 min
Vibration resistance50 Hz, 98 m/s2
WeightE54-CT1: Approx. 11.5 g
E54-CT3: Approx. 50 g
E54-CT1L: Approx. 14 g
E54-CT3L: Approx. 57 g
AccessoriesE54-CT3 Only
Armatures (2)
Plugs (2)
None

Heater Burnout Alarms and SSR Failure Alarms

CT input (for heater current detection)Models with detection for single-phase heaters: One input
Maximum heater current50 A AC
Input current indication accuracy± 5% FS ± 1 digit max.
Heater burnout alarm setting range *10.1 to 49.9 A (in units of 0.1 A)
Minimum detection ON time: 100 ms *3
SSR failure alarm setting range *20.1 to 49.9 A (in units of 0.1 A)
Minimum detection OFF time: 100 ms *4
*1. For heater burnout alarms, the heater current will be measured when the control output is ON, and the output will turn
ON if the heater current is lower than the set value (i.e., heater burnout detection current value).
*2. For SSR failure alarms, the heater current will be measured when the control output is OFF, and the output will turn
ON if the heater current is higher than the set value (i.e., SSR failure detection current value).
*3. The value is 30 ms for a control period of 0.1 s or 0.2 s.
*4. The value is 35 ms for a control period of 0.1 s or 0.2 s.