D4MC-5040 Công tắc hành trình Omron

377,000

Giao hàng COD toàn quốc

Out of stock

Mô Tả Sản Phẩm

D4MC-5040

Công tắc hành trình Omron

Economical, High Utility Enclosed Switch

Ratings

Rated voltage Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC
250 VAC
480 VAC
10
10
3
3
2.5
1.5
1.5
1.25
0.75
10
10
2.5
5
3
1.5
2.5
1.5
0.75
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
10
10
6
0.5
0.25
3
3
3
0.4
0.2
1.5
1.5
1.5
0.4
0.2
6
6
5
0.05
0.03
5
5
5
0.05
0.03
2.5
2.5
2.5
0.05
0.03
Inrush current NC 30 A max.
NO 15 A max.

Note:Note:

Note:The above figures are for steady-state currents.

Note:Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).

Note:Lamp load has an inrush current of 10 times the steady-state current.

Note:Motor load has an inrush current of 6 times the steady-state current.

Note:The above ratings were tested under the following conditions.
(1) Ambient temperature: +20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency: 20 operations/min

Characteristics

Degree of protection IP67
Durability Mechanical 10,000,000 operations min.
Electrical 500,000 operations min.
Operating speed 0.05 mm/s to 0.5 m/s *1
Operating
frequency
Mechanical 120 operations/min
Electrical 20 operations/min
Rated frequency 50/60 Hz
Insulation resistance 100 M Ω min. (at 500 VDC)
Contact resistance 15 m Ω max. (initial value for the built-in switch when tested alone)
Dielectric
strength
Between terminals of the same polarity 1,000 VAC, 50/60 Hz for 1 min
Between each terminal and non-
current-carrying part
2,000 VAC, 50/60 Hz for 1 min
Rated insulation voltage (Ui) 1,000 VAC
Pollution degree (operating environment) 3 (IEC947-5-1)
Protection against electric shock Class II
PTI (tracking characteristics) 175
Switch category D (IEC335)
Rated operating current (Ie) 10 A
Rated operating voltage (Ue) 250 VAC
Vibration
resistance
Malfunction 10 to 55 Hz, 1.5-mm double amplitude *2
Shock
resistance
Destruction 1,000 m/s2 min.
Malfunction 100 m/s2 min. *1 *2
Ambient operating temperature – 10 ° C to +80 ° C (with no icing)
Ambient operating humidity 35% to 95%RH
Weight Approx. 71 g (in case of panel mount plunger)

Note:Only for models with plungers. (Contact your OMRON representative for information on other models.)

Note:Less than 1 ms under a free state at the operating limits.

List of Models

Actuator Model
Panel mount plunger
d4mc lineup1 1
D4MC-5000
Panel mount roller plunger
d4mc lineup1 2
D4MC-5020
Panel mount crossroller plunger
d4mc lineup1 3
D4MC-5040
Hinge lever
d4mc lineup1 4
D4MC-1000
Short hinge lever
d4mc lineup1 5
D4MC-1020
Hinge roller lever
d4mc lineup1 6
D4MC-2000
Short hinge roller lever
d4mc lineup1 7
D4MC-2020
One-way action short hinge roller lever
d4mc lineup1 8
D4MC-3030

Note:Note:
1. Use Switches with molded terminals in locations subject to dirt, dust, oil drops, or high humidity. Models are available with lead wires on the right, on the left, and from the bottom.
2. Contact your OMRON representative for information on models certified for international standards.

Reviews

There are no reviews yet.

Be the first to review “D4MC-5040 Công tắc hành trình Omron”

Your email address will not be published. Required fields are marked *