Ratings

Rated voltageNon-inductive load (A)Inductive load (A)
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125 VAC
250 VAC
480 VAC
10
10
3
3
2.5
1.5
1.5
1.25
0.75
10
10
2.5
5
3
1.5
2.5
1.5
0.75
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
10
10
6
0.5
0.25
3
3
3
0.4
0.2
1.5
1.5
1.5
0.4
0.2
6
6
5
0.05
0.03
5
5
5
0.05
0.03
2.5
2.5
2.5
0.05
0.03
Inrush currentNC30 A max.
NO15 A max.

Note:Note:

Note:The above figures are for steady-state currents.

Note:Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).

Note:Lamp load has an inrush current of 10 times the steady-state current.

Note:Motor load has an inrush current of 6 times the steady-state current.

Note:The above ratings were tested under the following conditions.
(1) Ambient temperature: +20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency: 20 operations/min

Characteristics

Degree of protectionIP67
DurabilityMechanical10,000,000 operations min.
Electrical500,000 operations min.
Operating speed0.05 mm/s to 0.5 m/s *1
Operating
frequency
Mechanical120 operations/min
Electrical20 operations/min
Rated frequency50/60 Hz
Insulation resistance100 M Ω min. (at 500 VDC)
Contact resistance15 m Ω max. (initial value for the built-in switch when tested alone)
Dielectric
strength
Between terminals of the same polarity1,000 VAC, 50/60 Hz for 1 min
Between each terminal and non-
current-carrying part
2,000 VAC, 50/60 Hz for 1 min
Rated insulation voltage (Ui)1,000 VAC
Pollution degree (operating environment)3 (IEC947-5-1)
Protection against electric shockClass II
PTI (tracking characteristics)175
Switch categoryD (IEC335)
Rated operating current (Ie)10 A
Rated operating voltage (Ue)250 VAC
Vibration
resistance
Malfunction10 to 55 Hz, 1.5-mm double amplitude *2
Shock
resistance
Destruction1,000 m/s2 min.
Malfunction100 m/s2 min. *1 *2
Ambient operating temperature– 10 ° C to +80 ° C (with no icing)
Ambient operating humidity35% to 95%RH
WeightApprox. 71 g (in case of panel mount plunger)

Note:Only for models with plungers. (Contact your OMRON representative for information on other models.)

Note:Less than 1 ms under a free state at the operating limits.

List of Models

ActuatorModel
Panel mount plunger
D4MC-5000
Panel mount roller plunger
D4MC-5020
Panel mount crossroller plunger
D4MC-5040
Hinge lever
D4MC-1000
Short hinge lever
D4MC-1020
Hinge roller lever
D4MC-2000
Short hinge roller lever
D4MC-2020
One-way action short hinge roller lever
D4MC-3030

Note:Note:
1. Use Switches with molded terminals in locations subject to dirt, dust, oil drops, or high humidity. Models are available with lead wires on the right, on the left, and from the bottom.
2. Contact your OMRON representative for information on models certified for international standards.