D4E-1A10N Công tắc hành trình Omron

276 lượt xem

Ngày: 09/06/2019

Hết Hàng

Thông tin sản phẩm

759,000

Hết hàng

Xin vui lòng liên hệ theo thông tin dưới dây

0936.296.483 (Liên hệ mua hàng) Email: sales@minhquangelectric.com THỜI GIAN LÀM VIỆC: Thứ 2 - thứ 6 / 8:00 AM - 5:00 PM Thứ 7 / 9:00 AM - 11:00 AM (Email only)

0969.100.802 (Dịch vụ kỹ thuật) Email: services@minhquangelectric.com THỜI GIAN LÀM VIỆC: Thứ 2 - thứ 6 / 8:00 AM - 5:00 PM Thứ 7 / 9:00 AM - 11:00 AM (Email only)

D4E-1A10N

Công tắc hành trình Omron

Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E

TypeOne-touch connector
type
Screw terminal type
General-
purpose
Micro loadGeneral-
purpose
without cable
Micro load
without
cable
General-
purpose
with cable
Micro load
with cable
ActuatorModelModelModelModelModelModel
Roller plunger
D4E-1A[]0ND4E-2A10ND4E-1A20ND4E-2A20ND4E-1A21ND4E-2A21N
Crossroller
plunger
D4E-1B[]0ND4E-2B10ND4E-1B20ND4E-2B20ND4E-1B21ND4E-2B21N
Plunger
D4E-1C[]0ND4E-2C[]0ND4E-1C20ND4E-2C20ND4E-1C21ND4E-2C21N
Sealed roller
plunger
D4E-1D[]0ND4E-2D10ND4E-1D20ND4E-2D20ND4E-1D21ND4E-2D21N
Sealed crossroller
plunger
D4E-1E[]0ND4E-1E20ND4E-2E20ND4E-1E21ND4E-2E21N
Sealed plunger
D4E-1F[]0ND4E-2F10ND4E-1F20ND4E-2F20ND4E-1F21ND4E-2F21N
Roller lever
D4E-1G[]0ND4E-2G10ND4E-1G20ND4E-2G20ND4E-1G21ND4E-2G21N
One-way action
roller lever
D4E-1H00ND4E-1H20ND4E-2H20ND4E-1H21N

Note: 1. When ordering, specify the current type by replacing the blank box of the model number with 0 for AC connector
or 1 for DC connector.
2. For the plunger and lever actuator models, the NC and NO terminal indicators are reversed.
3. Models are also available with molded terminals and with molded terminals and operation indicators. Refer to
Catalog.

Plug

For models with connectors, select one of the specified Cables with Connectors (sockets) from the following table.

Applicable limit switchesCurrent TypeTypeNo. of conductorsCable lengthModel
D4E-[][]00NACStraight

d4e-[]n_lineup2_1
42 mXS2F-A421-D90-F
5 mXS2F-A421-G90-F
D4E-[][]10NDC2 mXS2F-D421-D80-F
5 mXS2F-D421-G80-F

Ratings

Rated voltageStandard loadMicro load
Non-inductive load (A)Inductive load (A)Non-inductive load (A)
Resistive loadLamp loadInductive loadMotor loadResistive load
NCNONCNONCNONCNONCNO
125 VAC
250 VAC
5 (1)
5 (1)
1.5 (1)
1.5 (1)
3 (1)
3 (1)
2 (1)
1
1 (1)
0.5
0.1
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
5 (1)
5 (1)
5 (1)
0.5
0.25




1.5 (1)
1.5 (1)
1.5 (1)
0.05
0.03




0.1
0.1
0.1

Minimum applicable loadStandard loadMicro load
160 mA at 5 VDC1 mA at 5 VDC
Inrush currentNC10 A max.
NO10 A max.

Note: 1. The above current ratings are for a standard current and the values in parentheses are for models with a
connector.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.

Characteristics

Degree of protectionIP67
Durability *Mechanical10,000,000 operations min.
Electrical500,000 operations min. (5 A at 250 VAC, resistive load)
5,000,000 operations min. (10 mA at 24 VDC, resistive load)
Operating speed0.1 mm/sec to 0.5 m/sec
Operating frequencyMechanical: 120 operations/min
Electrical: 30 operations/min
Rated frequency50/60 Hz
Insulation resistance100 MΩ min. (at 500 VDC)
Contact resistance15 mΩ max. (initial value for the built-in switch when tested alone)
Dielectric strengthBetween terminals of same
polarity
1,000 VAC, 50/60 Hz for 1 min
Between each terminal and
non-current-carrying metal
part
1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1)
Rated insulation voltage (Ui)250V
Pollution degree (operating environment)3 (EN60947-5-1)
Short-circuit protective device (SCPD)10 A fuse (type gG or gI, IEC60269 approved)
Conditional short-circuit current100 A (EN60947-5-1)
Conventional enclosed thermal current (Ithe)5 A (EN60947-5-1)
Protection against electric shockClass II (grounding not required with double insulation)
Vibration resistanceMalfunction10 to 55 Hz, 1.5-mm double amplitude
Shock resistanceDestruction1,000 m/s2 max.
Malfunction300 m/s2 max.
Ambient operating temperature-10°C to +80°C (with no icing)
Ambient operating humidity35% to 95%RH
WeightApprox. 86 g (in case of roller plunger)

Note: 1. The above values are initial values.
2. The above ratings may vary depending on the model. Contact your OMRON representative for further details.
* Durability values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to
70%RH.

NHẬN XÉT SẢN PHẨM